Drying is one of the most important methods for industrial processing while the granule moisture is a critical quality attribute (CQA) which has a significant influence on the finished product quality. In-line measurement of granule moisture during fluidized bed drying is getting more imperative to meet more stringent product quality specifications. Nowadays, several methods have been applied to measuring the granule moisture in-line. Comparing to other methods, microwave resonance (MR) technology provides more representative results due to its independency of both the particle density and the bed density. In the current study, one MR sensor was mounted onto an industrial fluidized bed dryer to monitor the real-time moisture of granules. The drying experiments were performed at different drying air temperatures and flow rates. The comparison between the results of in-line and off-line granule moisture measurements, namely MR technology and loss on drying caused by infrared light (LOD/IR), was presented. Furthermore, the influences of inlet air temperature and flow rate on the performance of the MR sensor were investigated. As a conclusion, the MR method, which is independent of the drying air temperature and flow rate, provided more accurate results when the granule moisture was below 25% (wet basis). Therefore, it is a promising method to be applied in real-time measurement of the granule moisture and predict the end-point in fluidized bed drying processes as well.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

466-470

Citation:

Online since:

March 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S.T.F. Mortier, T. De Beer, K.V. Gernaey, Mechanistic modelling of fluidized bed drying processes of wet porous granules: A review, European Journal of Pharmaceutics and Biopharmaceutics. 79 (2011) 205-225.

DOI: 10.1016/j.ejpb.2011.05.013

Google Scholar

[2] C. Buschmüller, W. Wiedey, C. Döscher, In-line monitoring of granule moisture in fluidized-bed dryers using microwave resonance technology, European Journal of Pharmaceutics and Biopharmaceutics. 69 (2008) 380-387.

DOI: 10.1016/j.ejpb.2007.09.014

Google Scholar

[3] F. Portoghese, F. Berruti, C. Briens, Continuous on-line measurement of solid moisture content during fluidized bed drying using triboelectric probes, Powder Technology. 181 (2008) 169-177.

DOI: 10.1016/j.powtec.2007.01.003

Google Scholar

[4] H.G. Wang, P.R. Senior, R. Mann, Online measurement and control of solids moisture in fluidised bed dryers, Chemical Engineering Science. 64 (12) (2009) 2893-2902.

DOI: 10.1016/j.ces.2009.03.014

Google Scholar

[5] T. De Beer, A. Burggraeve, M. Fonteyne, Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes, International Journal of Pharmaceutics, 417 (2011) 32-47.

DOI: 10.1016/j.ijpharm.2010.12.012

Google Scholar

[6] F. J. S. Nieuwmeyer, M. Damen, A. Gerich, Granule characterization during fluid bed drying by development of a near infrared method to determine water content and median granule size, Pharmaceutical Research. 24 (2007) 1854-1861.

DOI: 10.1007/s11095-007-9305-5

Google Scholar

[7] J. Mantanus, E. Ziémons, P. Lebrun, Moisture content determination of pharmaceutical pellets by near infrared spectroscopy: Method development and validation, Analytica Chimica Acta. 642 (2009) 186-192.

DOI: 10.1016/j.aca.2008.12.031

Google Scholar

[8] A. Miwa, T. Yajima, H. Ikuta, Prediction of suitable amounts of water in fluidized bed granulation of pharmaceutical formulations using corresponding values of components, International Journal of Pharmaceutics. 352 (2008) 202-208.

DOI: 10.1016/j.ijpharm.2007.10.044

Google Scholar

[9] F. Portoghese, F. Berruti, C. Briens, Use of triboelectric probes for on-line monitoring of liquid concentration in wet gas–solid fluidized beds, Chemical Engineering Science. 60 (22) (2005) 6043-6048.

DOI: 10.1016/j.ces.2005.03.042

Google Scholar

[10] V. Rimpiläinen, L.M. Heikkinen, M. Vauhkonen, Moisture distribution and hydrodynamics of wet granules during fluidized-bed drying characterized with volumetric electrical capacitance tomography, Chemical Engineering Science. 75 (2012) 220-234.

DOI: 10.1016/j.ces.2012.03.028

Google Scholar

[11] C.C. Corredor, D. Bu, D. Both, Comparison of near infrared and microwave resonance sensors for at-line moisture determination in powders and tablets, Analytica Chimica Acta. 696 (2011) 84-93.

DOI: 10.1016/j.aca.2011.03.048

Google Scholar

[12] J. Luypaert, D.L. Massart, Y. Vander Heyden, Near-infrared spectroscopy applications in pharmaceutical analysis, Ta lanta. 72 (3) (2007) 865-883.

DOI: 10.1016/j.talanta.2006.12.023

Google Scholar

[13] V. Lourenço, T. Herdling, G. Reich, Combining microwave resonance technology to multivariate data analysis as a novel PAT tool to improve process understanding in fluid bed granulation, European Journal of Pharmaceutics and Biopharmaceutics. 78 (3) (2011).

DOI: 10.1016/j.ejpb.2011.02.008

Google Scholar