Performance Study of Solar Chimney Power Plant System with a Sloped Collector

Article Preview

Abstract:

There is a solar chimney power plant system supported by southern sloped mountain for high latitudes. The sloped collector is built at suitable mountain hills, which also functions as a chimney. Then a short vertical chimney is added to install the vertical axis air turbine. Deduce and analysis the power and efficiency of the system. The result indicates that for northern latitude area near 35 degrees, the power and efficiency of the solar chimney power plant system with a appropriate sloped angle collector are higher than the solar chimney power plant system with a horizontal collector, besides, the system scale is bigger, the gap is more larger. Furthermore, the system can appropriately reduce the height of vertical chimney and construction problems.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

597-603

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lu Feng, Zhang Hua: Research and development of solar chimney power generation technology. ELECTRIC POWER,Vol.39 (2006), p.

Google Scholar

[2] Zhou Xinping, Yang Jiakuan, Xiao Bo: A novel concept for constructing a leaning solar chimney power plant supported by a mountain.RENEWABLE ENERGY, Vol.4 (2006),pp.9-11

Google Scholar

[3] Huang Guohua, Shi Yuchuan:Feasibility analysis of solar chimney power plant system supported by southern sloped mountain .SOLAR ENERGY. Vol.4 (2005), pp.46-47

Google Scholar

[4] Zhou Xinping: A dissertation submitted in partial fulfillment of the requirements for the degree of doctor of philosophy in engineering. Wu Han, Huazhong university of science and technology. (2007)

Google Scholar

[5] Duffie J A, Beckman W A: Solar Engineering of Thermal Processes. New York: Wiley Interscience, 1991, pp.24-27.

Google Scholar

[6] E.Bilgen, J.Rheault: Solar chimney power plants for high latitudes. Solar Energy, Vol.1 (2005), pp.449-458

DOI: 10.1016/j.solener.2005.01.003

Google Scholar

[7] Liu B.H.Y., and R.C. Jordan: The interrelationship and characteristic distribution of direct, diffuse and total solar radiation. Solar Energy. Vol.4 (1960)pp.1-19.

DOI: 10.1016/0038-092x(60)90062-1

Google Scholar

[8] Heaf, W., Friedrich, G., Mary G., Schlaich, J.:Part I:Principle and construction of the pilot plant in Manzanares. Int. J. Solar energy. Vol.2(1983),pp.3-20.

Google Scholar

[9] Bernardes, M.A., Dos, S., Voss, A., Weinrebe, G: Thermal and technical analyses of solar chimneys. Solar Energy. Vol.75(2003), p.511–524.

DOI: 10.1016/j.solener.2003.09.012

Google Scholar

[10] SCHL.AICH J: The solar chimney: Electricity from the sun. Maurer C, editor. Germany Geislingen.1995.

Google Scholar