Fire Behavior of Sandwich Panels for Roofing Applications

Article Preview

Abstract:

Cement-based multilayered panels represent a promising and cost-effective solution for the roofing of modern prefabricated buildings. Due to the spread of such technologies, it is deemed necessary to evaluate the structural performances also with reference to the fire scenario. In the framework of a research project financed by national and regional authorities, Politecnico di Milano coordinated a wide experimental campaign aimed at assessing the mechanical behavior of innovative composite elements (2.5 m wide, 5 m long). The paper presents the results pertaining to the full-scale test of a prototype at high temperatures - mainly focusing on Temperature-Time and Displacement-Time diagrams - and provides a fire resistance classification compatible with the observed failure mode.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

775-782

Citation:

Online since:

September 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] M. di Prisco, M. Colombo, FRC in thin-walled structures: Opportunities and threats, Proc. of 8th RILEM Int. Symp. on Fibre-Reinforced Concretes, PRO 088, (2012), 23-49.

Google Scholar

[2] M. di Prisco, D. Dozio, B. Belletti, On the fracture behaviour of thin-walled SFRC roof elements, Materials and Structures/Materiaux et Constructions, 46 (5), (2013), 803-829.

DOI: 10.1617/s11527-012-9935-x

Google Scholar

[3] M. Colombo, M. di Prisco, R. Felicetti, SFRC exposed to high temperature: Hot vs. residual characterization for thin walled elements, Cement and Concrete Composites, 58, (2015), 81-94.

DOI: 10.1016/j.cemconcomp.2015.01.002

Google Scholar

[4] H.W. Reinhardt, G.J. Parra-Montesinos and H. Garrecht, (Eds. ), Proceedings pro094: 7th International RILEM Workshop on High Performance Fiber Reinforced Cement Composites (HPFRCC7), (2015).

DOI: 10.51202/9783816793977

Google Scholar

[5] M. di Prisco, L. Ferrara, M. Lamperti, S. Lapolla, A. Magri, G. Zani, Sustainable roof elements: a proposal offered by cementitious composites technology, Innovative Materials and Techniques in Concrete Construction, (2012) 167-181.

DOI: 10.1007/978-94-007-1997-2_10

Google Scholar

[6] I.G. Colombo, A. Magri, G. Zani, M. Colombo and M. di Prisco, Erratum to: Textile Reinforced Concrete: experimental investigation on design parameters, Materials and Structures, (46)11 (2013) 1953-(1971).

DOI: 10.1617/s11527-013-0023-7

Google Scholar

[7] M. di Prisco, M. Colombo, G. Zani, M.C. Rampini, Existing industrial buildings: a sustainable solution for roofing rehabilitation, in: Strategies for Sustainable Concrete Structures SSCS 2015, Rio de Janeiro, Brazil, (2015).

Google Scholar

[8] G. Zani, M.C. Rampini, M. Colombo and M. di Prisco, Shear Behavior of Multilayered Panels for Roofing Rehabilitation, Ultra-High Performance Concrete and High Performance Construction Materials (27), Kassel University Press, (2016).

DOI: 10.4028/www.scientific.net/kem.711.775

Google Scholar

[9] A. Caverzan, M. Colombo, M. di Prisco, B. Rivolta, High performance steel fibre reinforced concrete: residual behaviour at high temperature, Materials and Structures, 48 (2015) 3317–3329.

DOI: 10.1617/s11527-014-0401-9

Google Scholar

[10] I. G. Colombo, M. Colombo, A. Magri, G. Zani, M. di Prisco, Textile Reinforced Mortar at High Temperatures, Applied Mechanics and Materials, 82 (2011) 202-207.

DOI: 10.4028/www.scientific.net/amm.82.202

Google Scholar

[11] G. Zani, High Performance Cementitious Composites for Sustainable Roofing Panels, PhD Thesis, Politecnico di Milano, (2013).

Google Scholar

[12] F. Lo Monte, C. Rossino and R. Felicetti, Spalling test on concrete slabs under biaxial membrane loading,  in: Proc. 4th International Workshop on Concrete Spalling due to Fire Exposure (IWCS), Leipzig, Germany, (2015).

DOI: 10.1617/s11527-019-1318-0

Google Scholar