Degradation Mechanism of Dissimilar Metal Weld Joints on Steam Generator Collectors VVER 440MW Type

Article Preview

Abstract:

Indications were detected on dissimilar metal welds (DMW) of steam generators (SG) after 20 years of operation during NDT inspections. Indications started slowly growth every year. DMW on SGs had to be repaired. Paper describes experimental analysis and degradation mechanism of SG weld joints failures.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

134-137

Citation:

Online since:

June 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Junek L., et al., Experimental program for evaluation of heterogeneous welded joint SG46 with defect, the report ÚAM Brno, archival No. 5160/13, Revision 1, Brno, January 2013 (in Czech).

Google Scholar

[2] Junek L., Cutting of segment with a defect of heterogeneous weld joint SG46 for the experimental program, the report ÚAM Brno, archival No. 5161/13, Revision 2, Brno, January 2013 (in Czech).

Google Scholar

[3] Ernestová M., et al., Experimental program for the evaluation of heterogeneous welded joint SG46 with defect. Results of the experimental program, the report ÚJV Řež, registration number DITI 2302/152, ÚJV Řež, March 2013 (in Czech).

Google Scholar

[4] Matocha K., et al., Final report. Material analyzes on samples supplied to defect from SG46 EDU, report MMV, archival No. Z-/2013, Ostrava, March 2013 (in Czech).

Google Scholar

[5] Siegl J., et al., Defect analysis of heterogeneous weld joint SG46, the report ČVUT, archival No. E-KMAT-878/13, Prague, March (2013).

Google Scholar

[6] Corrosion and protection of materials, a textbook designed for full-time study, Faculty of Production Technology and Management University JE Purkyně in Ustí nad Labem, April (2012).

Google Scholar