The paper describes the shaking table performance of a half-scale two-story steel moment frame with asymmetric friction connections (AFCs) at the column bases and at the beam ends. The results showed that the beam ends and the base-column joints exhibited bilinear and trilinear response respectively. Residual drifts were less than 0.2% for shake table trials up to 3% peak inter-story drift. Even at a peak inter-story drift of 6.5%, the residual drift response was still only 0.7%.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

400-405

Citation:

Online since:

February 2018

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2018 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yang TS, Popov EP. (1995). Experimental and analytical studies of steel connections and energy dissipators, Report No. UCB/EERC-95/13, Earthquake Engineering Research Centre: Berkeley, California.

Google Scholar

[2] Khoo H.H., Clifton C, MacRae G., Zhou H. and Ramhormozian Sh. (2014). Proposed design models for the asymmetric friction connection, Earthquake Engineering & Structural Dynamics, DOI: 10. 1002/eqe. 2520.

DOI: 10.1002/eqe.2520

Google Scholar

[3] Clifton, G.C. (1996). Development of Perimeter Moment-Resisting Steel Frames Incorporating Semi-Rigid Elastic Joints, New Zealand National Society for Earthquake Engineering Conference, 177-184.

Google Scholar

[4] Clifton C. (2005). Semi-rigid joints for moment-resisting steel framed seismic-resisting systems, PhD Thesis, Department of Civil and Environmental Engineering, University of Auckland.

Google Scholar

[5] MacRae, G. A., Clifton, G. C., Mackinven, H., Mago, N., Butterworth, J., and Pampanin, S. (2010). The sliding hinge joint moment connection, NZSEE Bull., 43(3), 202–212.

DOI: 10.5459/bnzsee.43.3.202-212

Google Scholar

[6] Chanchí, J. C., MacRae, G. A., Chase, J. G., Rodgers, G. W., and Clifton, C. G. (2012).

Google Scholar

[7] Chanchí, J. C., Xie, R., MacRae, G., Chase, G., Rodgers, G., and Clifton, C. (2014). Low-damage braces using asymmetrical friction connections (AFC), NZSEE Conf., The New Zealand Society for Earthquake Engineering, Auckland, New Zealand.

Google Scholar

[8] Borzouie J, MacRae G. A., Chase J. G., Rodgers G. W., and Clifton G. C. (2015).

Google Scholar

[9] Borzouie J, MacRae G. A., Chase J. G., Rodgers G. W., and Clifton G. C. (2015), Experimental studies on cyclic performance of column base weak axis aligned asymmetric friction connection, Journal of Constructional Steel Research, 112, 252–262.

DOI: 10.1016/j.jcsr.2015.05.007

Google Scholar

[10] NZS 1170. 5: 2004. Structural Design Actions Part 5: Earthquake Actions New Zealand. Standards New Zealand: Wellington, New Zealand, (2004).

Google Scholar

[11] MacRae, G. A., Clifton, G. C., (2015). Research on seismic performance of steel structures, Steel Innovations 2015 Conference Auckland.

Google Scholar