Influence of Freeze/Thaw and Alkaline Environment on the Mechanical Properties of a C-FRCM System Bonded on Masonry Substrate

Article Preview

Abstract:

The Fabric Reinforced Cementitious Matrix (FRCM) system in the last two decades was used to strengthen and rehabilitate historical masonry structures as an alternative of the well-known Fiber-Reinforced Polymer (FRP) system. The FRCM systems consist of different types of fiber in form of fabric mesh immersed in a cementitious/hydraulic or lime matrix; they present better compatibility with the substrate and less limitations in heritage applications. However, the durability and the interaction FRCM-substrate under the artificial aging mechanism in aggressive environment is not well known. The paper reports and discuss the first results of an experimental program planned to investigate the durability of some FRCM systems. The effects of the freeze/thaw and alkaline environment on both the mechanical properties of the FRCM coupons and the bond FRCM-to-masonry substrate were analyzed by the results of direct tensile and single-lap shear tests.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

27-34

Citation:

Online since:

April 2022

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2022 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Cascardi A., Leone M., Aiello M. A., Transversal joining of multi-leaf masonry through different types of connector: Experimental and theoretical investigation. Const. Build. Mat.,2020, 265.

DOI: 10.1016/j.conbuildmat.2020.120733

Google Scholar

[2] Franzoni E., Rising damp removal from historical masonries: a still open challenge. Constr. Build. Mater. 54 (2014) 123-136.

DOI: 10.1016/j.conbuildmat.2013.12.054

Google Scholar

[3] Bellini A., Bovo M., Mazzotti C., Experimental and numerical evaluation of fiber-matrix interface behavior of different FRCM systems, Composites Part B: Engineering, 2019, 161411–426.

DOI: 10.1016/j.compositesb.2018.12.115

Google Scholar

[4] Ascione L, De Felice G, De Santis S. A qualification method for externally bonded Fibre Reinforced Cementitious Matrix (FRCM) strengthening systems. Composites Part B: Engineering 2015; 78: 497–506.

DOI: 10.1016/j.compositesb.2015.03.079

Google Scholar

[5] Franzoni E, Santandrea M, Gentilini C, Fregni A, Carloni C. The role of mortar matrix in the bond behavior and salt crystallization resistance of FRCM applied to masonry. Construction and Building Materials 2019; 209: 592–605.

DOI: 10.1016/j.conbuildmat.2019.03.059

Google Scholar

[6] Ceroni F, Bonati A, Galimberti V, Occhiuzzi A. Effects of Environmental Conditioning on the Bond Behavior of FRP and FRCM Systems Applied to Concrete Elements. Journal of Engineering Mechanics 2018; 144(1): 04017144.

DOI: 10.1061/(asce)em.1943-7889.0001375

Google Scholar

[7] Donnini J. Durability of glass FRCM systems: Effects of different environments on mechanical properties. Composites Part B: Engineering, 2019; 174: 107047.

DOI: 10.1016/j.compositesb.2019.107047

Google Scholar

[8] Al-Lami, K.; D'Antino, T.; Colombi, P. Durability of Fabric-Reinforced Cementitious Matrix (FRCM) Composites: A Review. Appl. Sci., 2020,10,.

DOI: 10.3390/app10051714

Google Scholar

[9] Arboleda A., Babaeidarabad S, Hays C.D., Nanni A. Durability of fabric reinforced cementitious matrix (FRCM) composites. The 7th International Conference on FRP Composites in Civil Engineering, CICE (2014).

Google Scholar

[10] Linea Guida per la identificazione, la qualificazione ed il controllo di accettazione di compositi fibrorinforzati a matrice inorganica (FRCM) da utilizzarsi per il consolidamento strutturale di costruzioni esistenti. Consiglio Superiore Lavori Pubblici, Serv. Tecnico Centrale, Rome, (2018).

DOI: 10.3221/igf-esis.12.04

Google Scholar

[11] CEN EN 1015-11:1999/A1:2006. Methods of test for mortar for masonry - Part 11: Determination of flexural and compressive strength of hardened mortar. CEN, Brussels, (2006).

DOI: 10.3403/01905442

Google Scholar

[12] CEN EN 772-1:2011/A1:2015. Methods of test for masonry units - Part 1: Determination of compressive strength. CEN, Brussels, (2015).

Google Scholar

[13] A. Iorfida, S. Candamano, F. Crea, L. Ombres, S. Verre P. De Fazio, Bond Behaviour of FRCM Composites: Effects of High Temperature, Key Eng Mat., 2018, 817,161-166.

DOI: 10.4028/www.scientific.net/kem.817.161

Google Scholar