Evaluation of Load Parameters and Hold Time of a Vickers Ultra-Micro Hardness Tester for Measure of Hardness and Modulus of Elasticity of Dental Composites

Article Preview

Abstract:

The aim of this study was to standardize the parameters for testing the hardness and elastic modulus for dental composites. It used the equipment Dynamic Ultra Micro Hardness Tester DUH-211 / DUH-211S (Shimadzu) varying the load and the hold time. two composites were used with various inorganic particles that were embedded and sanded for the assay. one Vickers indenter was used being held nine rows with ten penetrations. For each composite loads were used (20, 50 and 100gf) and times (zero, five and ten seconds). The results showed that the effect of the load and the hold time had influence on the modulus and hardness values of the studied composites. The authors concluded that loads and hold larger team showed greater stability of hardness values and modulus of elasticity for the studied composites and these values for both hybrid composites as for nanoparticulate were dependent on load and time.

You might also be interested in these eBooks

Info:

* - Corresponding Author

[1] J.L. Ferracane: Dent. Mater. V. 27 (1) (2011), p.29.

Google Scholar

[2] K.J. Anusavice: Propriedades mecânicas dos materiais dentários. In: Anusavice KJ. Phillips, materiais dentários. Rio de Janeiro12. ed. Elsevier (2013), p.529.

DOI: 10.47749/t/unicamp.2014.937433

Google Scholar

[3] A. Garcia, J.A. Spim, C.A. Santos: Ensaio dos materiais. (Editora LTC Rio de Janeiro, 2008).

Google Scholar

[4] R. Hirata, A. H Mazzeto, E. Yao: Jornal Brasileiro de Clínica & Estética em Odontologia Vol. 4 (19) (2012).

Google Scholar

[5] W.D. Callister, Jr.: Ciência e Engenharia de Materiais: Uma Introdução. LTC 5º. ed. Rio de Janeiro, 2000).

Google Scholar

[6] G.F. Barbosa: Análise de Metodologias de Microdureza aplicadas a Compósitos: é possível comparar resultados utilizando-se diferentes protocolos? Doutorado (Tese). Porto Alegre, 2010. Pontifícia Universidade Católica do Rio Grande do Sul (PUC). (RS).

DOI: 10.24873/j.rpemd.2021.11.847

Google Scholar

[7] American Society for Testing and Materials ASTM E 384-99, Standart test method for microindentation hardness of materials, in: 2000 Annual Book of ASTM Standarts, ASTM, Philadelphia PA, 2000 pp.406-429.

Google Scholar

[8] I. Urabe, S. Nakajima, H. Sano, J. Tagami: Am. J. Dent. Vol. 3 (2000), p.129.

Google Scholar

[9] R.R. Silveira. Pesq. Bras. Odontoped. Clin. Integr. Vol. 12 (4) (2012), p.529.

Google Scholar

[10] M. Hosseinalipour et al.: J. Prosthodont. Vol. 19 (2) (2010), p.112.

Google Scholar

[11] C.L.M. Silva, T.C. F M. Silva, C.F. Carvalho, T. Camidu, J.P. Gouvêa, J.F.C. Lins: Análise da rugosidade e da morfologia de compósitos, utilizados em Odontologia. In 4º National Meeting of Biomechanical Enginering. Vitória/ E. S, Brasil, 2013 p.77.

Google Scholar

[12] T.C.F. Silva et al.: Materials Science Forum Vol. 820 (2015), p.320.

Google Scholar

[13] S. El-Safaty et al.: Dent Mater. Vol. 28 (12) (2012), p.1292.

Google Scholar

[14] V. Soprano: Estudo de parâmetros para ensaios de microdureza em amálgama de prata, resina composta, dentina e esmalte bovinos. Mestrado (Dissertação). São Paulo, 2007. Universidade de São Paulo (USP/ODONTO). (SP).

DOI: 10.11606/d.23.2008.tde-09042009-121826

Google Scholar

[15] A. Garcia, J.A. Spim, C.A. Santos: Ensaio dos Materiais. (Editora LTC Rio de Janeiro, 2008).

Google Scholar

[16] T.M.S. Simões: Saber Científico Vol. 4 (2) (2015), p.67.

Google Scholar

[17] D.A. Lucca, K. Hermann, M.J. Klopfstein: CIRP Annals. Vol. 59 (2) (2010), p.803.

Google Scholar

[18] M.G. P Couto et. al.: Rev. FOB Vol. 8 (2000), p.38.

Google Scholar

[19] I. Hubbezoglu et. al.: Dent. Mater. Vol. 26 (6) (2007), p.845.

Google Scholar

[20] C.R.G. BENGSTON: Estudo in vitro da influência da dureza e módulo de elasticidade de sistemas adesivos na resistência de união á dentina humana. Doutorado (Tese). São Paulo, 2010. Universidade de São Paulo (USP/ODONTO). (SP).

DOI: 10.11606/t.23.2011.tde-02052011-120506

Google Scholar

[21] W.P. Freire et al. Avaliação da microdureza dos materiais restauradores estéticos. In: XX Encontro do Grupo Brasileiro de Professores de Dentística. Anais.. São Paulo, SP. (2013).

Google Scholar

[22] J.L.N. Araújo: Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida. Doutorado (Tese). São Paulo, 2013. Universidade de São Paulo (USP/ODONTO). (SP).

DOI: 10.11606/t.23.2013.tde-10092013-200103

Google Scholar

[23] R.J. Crawford: Polymer testing. Vol. 3 (1982), p.37.

Google Scholar

[24] J. Lopez: Literature Review Polymer Testing Vol. 12 (1993), p.437.

Google Scholar

[25] L.V.S. Pabis: Comportamento bimodular em osso cortical e novo método para calcular o módulo de elasticidade em resinas compostas. Doutorado (Tese). São Paulo, 2014. Universidade de São Paulo (USP/ODONTO). (SP).

DOI: 10.11606/t.23.2015.tde-18032015-164615

Google Scholar