Study on Influencing Factors of Noise Reduction Performance of Pervious Concrete
Abstract:
In this experiment, four kinds of pervious concrete with different porosity (10%, 15%, 20%, 25%), four kinds of paste coating thickness (0.3mm, 0.5mm, 0.7mm, 0.9mm) and four kinds of thickness (30mm, 40mm, 50mm, 60mm) were prepared and their sound absorption coefficients under different frequency bands were tested. The results show that with the increase of target porosity, the thickness of paste coating and the thickness of pervious concrete, the sound absorption coefficient of pervious concrete increases firstly and then decreases. Through comprehensive consideration, when the target porosity is 18%, the thickness of paste coating is 0.5mm and the thickness is 40mm, pervious concrete has the best noise reduction effect. It provides a technical basis for the design of pervious concrete with noise reduction function.
Info:
Periodical:
Pages:
106-113
Citation:
Online since:
September 2019
Authors:
Price:
Сopyright:
© 2019 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: