Employment of Double-Panel Casing for Active Reduction of Device Noise

Article Preview

Abstract:

The idea of active casing is an approach to reduce device and machinery noise by controlling vibration of casing walls. The sound insulation efficiency of this technique for a single-plate casing was confirmed by the authors in previous publications. However, under specific circumstances, a dedicated double-panel structure can yield even higher noise reduction. The aim of this paper is to propose and evaluate by means of laboratory experiments the performance of a double-panel casing in comparison with a single-panel casing. An adaptive control strategy based on the Least Mean Square (LMS) algorithm is used to update control filter parameters. A low-frequency noise in the range up to 250 Hz is considered. Obtained results are reported, discussed, and conclusions for future research are drawn.

You might also be interested in these eBooks

Info:

Periodical:

Solid State Phenomena (Volume 248)

Pages:

27-34

Citation:

Online since:

March 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] D. Bismor, Comments on A New Feedforward Hybrid ANC System, IEEE Signal Processing Letters, 21 (2014) 635-637.

DOI: 10.1109/lsp.2014.2310783

Google Scholar

[2] D. Bismor, Comments on A New Feedforward Hybrid ANC System, – an Addendum, IEEE Signal Processing Letters, 21 (2014) 642-642.

DOI: 10.1109/lsp.2014.2310779

Google Scholar

[3] K. Chen, R. Paurobally, J. Pan and X. Qiu, Improving active control of fan noise with automatic spectral re-shaping for reference signal, Applied Acoustics, 87 (2015) 142-152.

DOI: 10.1016/j.apacoust.2014.07.003

Google Scholar

[4] Y. Xiao, A new efficient narrowband active noise control system and its performance analysis, Audio, Speech, and Language Processing, IEEE Transactions on, 19. 7 (2011) 1865-1874.

DOI: 10.1109/tasl.2010.2101598

Google Scholar

[5] K. Mazur and M. Pawelczyk, Active Noise Control with a single nonlinear control filter for a vibrating plate with multiple actuators, Archives of Acoustics, 38. 4 (2013) 537–545.

DOI: 10.2478/aoa-2013-0063

Google Scholar

[6] Z. Qiu and B. Ma, Adaptive resonant vibration control of a piezoelectric flexible plate implementing Filtered-X LMS algorithm, International Journal of Acoustics and Vibration, 19. 4 (2014) 224-239.

DOI: 10.20855/ijav.2014.19.4355

Google Scholar

[7] K. Szemela, W.P. Rdzanek and D. Pieczonka, The total acoustic power of a clamped circular plate located at the boundary of three-wall corner region, Acta Physica Polonica, 119. 6A (2011) 1050-1060.

DOI: 10.12693/aphyspola.119.1050

Google Scholar

[8] J.P. Carneal and C.R. Fuller, An analytical and experimental investigation of active structural acoustic control of noise transmission through double panel systems, Journal of Sound and Vibration 272. 3 (2004) 749-771.

DOI: 10.1016/s0022-460x(03)00418-8

Google Scholar

[9] J. Legault and N. Atalla, Sound transmission through a double panel structure periodically coupled with vibration insulators, Journal of sound and vibration 329. 15 (2010) 3082-3100.

DOI: 10.1016/j.jsv.2010.02.013

Google Scholar

[10] O.E. Kaiser, S.J. Pietrzko and M. Morari, Feedback control of sound transmission through a double glazed window, Journal of Sound and Vibration 263. 4 (2003) 775-795.

DOI: 10.1016/s0022-460x(02)01259-2

Google Scholar

[11] S.J. Pietrzko, Contributions to noise and vibration control technology, AGH University of Science and Technology Press, Cracow, (2009).

Google Scholar

[12] O.E. Kaiser, Active control of sound transmission through a double wall structure. Diss., Technische Wissenschaften ETH Zürich, Nr. 14109, (2001).

Google Scholar

[13] S. Wrona and M. Pawelczyk, Active reduction of device multi-tonal noise by controlling vibration of multiple walls of the device casing, Proceedings of the 19th International Conference on Methods and Models in Automation and Robotics, IEEE, (2014).

DOI: 10.1109/mmar.2014.6957437

Google Scholar

[14] S. Wrona and M. Pawelczyk, Controllability-oriented placement of actuators for active noise-vibration control of rectangular plates using a memetic algorithm, Archives of Acoustics, 38. 4 (2013) 529-536.

DOI: 10.2478/aoa-2013-0062

Google Scholar

[15] S. Wrona, M. Pawelczyk and J. Wyrwal, Optimal placement of elastically mounted vibration actuators on a plate, for active noise-vibration control, Proceedings of 18th Domestic Conference on Automatic Control, 8-10 September, Wroclaw, Poland, (2014).

Google Scholar

[16] S. Wrona and M. Pawelczyk, Application of memetic algorithm to placement of sensors for active noise-vibration control, Mechanics and Control, 32. 3 (2014) 122-128.

DOI: 10.7494/mech.2013.32.3.122

Google Scholar

[17] K. Mazur and M. Pawelczyk, Active noise-vibration control using the filtered-reference LMS algorithm with compensation of vibrating plate temperature variation, Archives of Acoustics, 36. 1 (2011) 65-76.

DOI: 10.2478/v10168-011-0006-z

Google Scholar

[18] M. Pawelczyk, Active noise control - a review of control-related problems, Archives of Acoustics, 33. 4 (2008) 509-520.

Google Scholar

[19] J. Kowal, J. Pluta, J. Konieczny, A. Kot, Energy recovering in active vibration isolation system - results of experimental research, Journal of Vibration and Control 14. 7 (2008) 1075-1088.

DOI: 10.1177/1077546308088980

Google Scholar

[20] W. Raczka, M. Sibielak, J. Kowal, J. Konieczny, Application of an SMA Spring for Vibration Screen Control, Journal of Low Frequency Noise, Vibration and Active Control, 32. 1 (2013) 117-132.

DOI: 10.1260/0263-0923.32.1-2.117

Google Scholar