Sort by:
Publication Type:
Open access:
Publication Date:
Periodicals:
Search results
Online since: May 2014
Authors: Véronique Favier, Nicolas Ranc, André Chrysochoos, Antoine Blanche, Ngoc Lam Phung
Energy dissipation and self-heating due to microplastic deformation mechanisms at very high cycle fatigue for single-phase ductile metals
Véronique FAVIER1,a, Antoine BLANCHE2,b, Ngoc Lam PHUNG1,c, Nicolas RANC1,d, André CHRYSOCHOOS2,e
1Arts et Métiers Paristech, Laboratoire Procédés et Ingénierie en Mécanique et Matériaux (PIMM), UMR CNRS 8006, 151 boulevard de l'Hôpital 75013 Paris, France
2Laboratoire de Mécanique et Génie Civil (LMGC), Université Montpellier 2, CNRS, Place Eugène Bataillon, 34090 Montpellier, France
averonique.favier@ensam.eu, bantoine.blanche@univ-montp2.fr, cngoclam250@yahoo.com, dnicolas.ranc@ensam.eu, eandre.chrysochoos@univ-montp2.fr
Keywords: ultrasonic fatigue, copper, persistent slip bands, heating, fatigue limit
Abstract.
Some mechanical components, such as pistons, rotating axes, in the transportation and more generally engineering industry, have been designed previously using fatigue resistance data at lower numbers of cycles (<107 cycles ; the regime of high cycle fatigue, HCF) whereas they must endure cyclic loading for a number of cycles higher than >109 cycles [1].
Some mechanical components, such as pistons, rotating axes, in the transportation and more generally engineering industry, have been designed previously using fatigue resistance data at lower numbers of cycles (<107 cycles ; the regime of high cycle fatigue, HCF) whereas they must endure cyclic loading for a number of cycles higher than >109 cycles [1].
Online since: December 2018
Authors: Pascal Casari, Mireille Richard-Plouet, Pierre Antoine Dubos, Quentin Hatte, Pierre-Yves Jouan, Samuel Branchu, Nadia Guitter
Stress Gradient Determination in Anti-Corrosion Multilayer Coating
DUBOS Pierre-Antoine1,a*, HATTE Quentin1,2,b, CASARI Pascal1,c, RICHARD-PLOUET Mireille3,d, JOUAN Pierre-Yves3,e, BRANCHU Samuel1,f and GUITTER Nadia4, g
1Université de Nantes, GeM, Institut de Recherche en Génie Civil et Mécanique, 58 rue Michel Ange, BP420, 44600 Saint-Nazaire, France
2Institut de Recherche Technologique Jules Verne, IRT, Chemin du Chaffault, 44340 Bouguenais, France
3Université de Nantes, IMN, Institut des Matériaux Jean Rouxel, 2 rue de la Houssinière, Nantes, France
4Socomore, avenue Paul Duplaix, ZI Du Prat, 56000 Vannes, France
apierre-antoine.dubos@univ-nantes.fr, bquentin.hatte@irt-jules-verne.fr, cpascal.casari@univnantes.fr, dMireille.Richard@cnrs-imn.fr, ePierre-Yves.Jouan@cnrsimn.fr, fsamuel.branchu@univ-nantes.fr, gn.guitter@socomore.com
Keywords: Stress, Coating, Thin film, Sol-gel, PVD, Multilayer.
Petrov, Interface microstructure engineering by high power impulse magnetron sputtering for the enhancement of adhesion, J.
Petrov, Interface microstructure engineering by high power impulse magnetron sputtering for the enhancement of adhesion, J.
Online since: August 2013
Authors: Xiao Chun Liu, Li Na Zhou, Jie Bai
Meanwile, more other fields as industry, transportation, civil construction, public institutions, residents living, agriculture and rural areas have been brought in the key areas of energy-saving service.
For the key and common technical problems, the government should organize scientific research units, enterprise innovation platform and engineering laboratory to work together for specialized research.
For the key and common technical problems, the government should organize scientific research units, enterprise innovation platform and engineering laboratory to work together for specialized research.
Online since: June 2019
Authors: Xiao Ting Zhang, Fei Peng Zhang, Xiao Wang, Liu Shuan Yang
Conductivity of Porous Phosphate-Silicate Glass Synthesized with Non-Ionic Surfactant
Xiaoting Zhanga*, Feipeng Zhangb, Xiao Wangc, Liushuan Yangd
Department of Civil & Material Engineering, Henan University of Urban Construction, Mingyue Road, Pingdingshan, Henan 467036, P.
Online since: August 2019
Authors: Salah Al-Toubat, M. Talha Junaid, Fatima Yousuf
Talha Junaid1,b* and Salah Altoubat1,c
1Department of Civil and Environmental Engineering, University of Sharjah, U.A.E
afyousuf@sharjah.ac.ae, bmjunaid@sharjah.ac.ae, csaltoubat@sharjah.ac.ae
Keywords: Alkali-activated concrete, Fly ash, GGBFS, Drying shrinkage, Curing
Abstract.
Online since: August 2018
Authors: Pavla Ryparová, Lukáš Balík
Methodology for Determination of the Requirement of Repair of External Facades of ETICS due to the Occurrence of Microorganisms
RYPAROVÁ Pavla1,a* and BALÍK Lukáš2,b
1Department of Building Structures, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 166 27 Prague 6, Czech Republic
2Department of Building Materials, Klokner institute, Czech Technical University in Prague, Šolínova 7, 166 08 Prague 6, Czech Republic
apavla.ryparova@fsv.cvut.cz, blukas.balik@cvut.cz
Keywords: ETICS, microorganism, biodegradation, rehabilitation
Abstract.
Online since: August 2019
Authors: Evgeny Doronin, Boris Ivanov, Volodymyr Konoval, Alexey Vasilchenko
Effect of Residual Deformation of a Steel Column on its Fire Resistance under Combined Exposure "Explosion-Fire"
Vasilchenko Alexey1,a*, Doronin Evgeny2,b, Ivanov Boris3,c, Konoval Vladimir4,d
1National University of Civil Defence of Ukraine, 94, Chernishevska st., Kharkov, Ukraine, 61023
2V.
Engineering Mechanics. 131(6) (2005) 606–616
Engineering Mechanics. 131(6) (2005) 606–616
Online since: July 2014
Authors: Jie Fang
Network Coordinated Ramp Metering Control Strategy:
Optimization and Evaluation
Jie fang1,a
1College of Civil Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
afangj1984@hotmail.com
Keywords:Ramp Metering; Active Traffic Control; Traffic Simulation
Abstract.The Ramp Metering (RM) control has been proven to be an effective measure for improving the efficiency of expressway operations.