p.371
p.376
p.382
p.387
p.391
p.395
p.399
p.404
p.410
Study on Noise Control of Fan with Air Suction
Abstract:
Fan is a pneumatic device in the 4ZTL-1800 combine harvester threshing prior to cutting. Based on the prophase search result that fan noise is highest when fan rotates at 1200r/min, in order to decrease noise of it, sigle-microperferated-panel muffler, double-microperferated-panel muffler and interposition muffler were designed and tested. The results show that double-microperferated-panel muffler is best and sound power level of fan is decreased 11dB, and that interposition muffler is better, and that sigle-microperferated-panel muffler is worst to descrease fan noise. Through contrast on transmission power loss of different mufflers, cone-shaped double-microperferated-panel muffler is verified to be best for noise control of fan.
Info:
Periodical:
Pages:
391-394
Citation:
Online since:
November 2011
Authors:
Keywords:
Price:
Сopyright:
© 2012 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: