Modeling and Development of a Robotized Hand-Hold Bone Cutting Device

Article Preview

Abstract:

Many surgical operations such as Total knee arthroplasty (TKA) and Total hip arthroplasty (THA) as well as bone fracture reposition require bone cutting manipulations. We have been developing a two degree of freedom robotized bone cutting hand-hold device. It is intended to execute cutting operation in order to avoid problems as accuracy errors, overheating and to obtain smooth bone surface. Surgeons have to orientate and hold the cutting robot, maintaining the contact with the bone during the operation all the time while the device executes manipulation automatically. Dynamical model based on graph theory and the orthogonally principle is derived for considered electromechanical system. Design of the mechanical part of bone cutting robotized device is provided

You might also be interested in these eBooks

Info:

Periodical:

Pages:

479-483

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C. Plaskos, P. Cinquin, S. Lavalle´ e and A. Hodgson. Praxiteles: a miniature bone-mounted robot for minimal access total knee arthroplasty, Internat. Jour. Medical Robotics and Computer Assisted Surgery, vol. 1 (4), p.67–79, (2005).

DOI: 10.1002/rcs.59

Google Scholar

[2] W. Saensupho and J. Suthakorn. A Novel Conceptual Design on Robotic Bone-Cutting Device Based on Kinematic Analysis: Toward Development of A Novel Robot-Assisted Total Knee Replacement Surgical System, 2011, International Conference on Computer Control and Automation (ICCCA 2011), pp.139-142, (2011).

Google Scholar

[3] M. Hsieh, M. Tsai, and Y. Yeh. An amputation simulator with bone sawing haptic interaction, Biomed. Eng. Appl. Basis. Comm., 2006, October, vol. 18, pp.229-236.

DOI: 10.4015/s1016237206000361

Google Scholar

[4] O. Cartiaux, L. Paul, P. Docquier, B. Raucent, E. Dombre, X. Banse. Computer-assisted and robot-assisted technologies to improve bone-cutting accuracy when integrated with a freehand process using an oscillating saw, Journal Bone and Joint Surgery Am. 2010, September 1; vol. 92 (11), pp.2076-82, (2010).

DOI: 10.2106/jbjs.i.00457

Google Scholar

[5] N. Sugita, T. Osa and M. Mitsuishi. Analysis and estimation of cutting-temperature distribution during end milling in relation to orthopedic surgery, Medical Engineering & Physics, vol. 31, p.101–107, (2009).

DOI: 10.1016/j.medengphy.2008.05.001

Google Scholar

[6] P. Gomes. Surgical robotics: Reviewing the past, analyzing the present, imagining the future, Robotics and Computer-Integrated Manufacturing, vol. 27, p.261–266, (2011).

DOI: 10.1016/j.rcim.2010.06.009

Google Scholar

[7] M. Shoham, M. Burman, E. Zehavi, L. Joskowicz, E. Batkilin and Y. Kunicher. Bone-Mounted Miniature Robot for Surgical Procedures: Concept and Clinical Applications, IEEE Trans. Robotics and Automation, vol. 19, (5), pp.893-901, (2003).

DOI: 10.1109/tra.2003.817075

Google Scholar

[8] A. Korff, M. Niggemeyer, M. de la Fuente and K. Radermacher, Control and safety architecture for a modular medical robot, Informatik 2009: Im Focus das Leben, Beiträge der 39. Jahrestagung der Gesellschaft für Informatik e.V. (GI), 28. 9. -2. 10. 2009, Lübeck, Proceedings 01/(2009).

Google Scholar

[9] G. Boiadjiev, and L. Lilov, Dynamics of multicomponent systems based on the orthogonality principle. Journal of Theoretical and Applied Mechanics, Year XXIV(1), 1993, pp: 11–26.

Google Scholar

[10] Information on the http: /whruijin. en. made-in-china. com/product/feDmQMwGZNWd/China-Orthopedic-Oscillating-Saw-Attachment-RJ1091-. html.

Google Scholar

[11] Maxon motor catalogue 2012/13, pp: 177.

Google Scholar

[12] Maxon motor catalogue 2012/13, pp: 239.

Google Scholar

[13] Information on the http: /www. kssballscrew. com/us/pdf/catalog/vol. 25. 0_MoBo_MB_A3. pdf.

Google Scholar

[14] Information on the http: /www. kyowa-ei. co. jp/eng/product/sensors/loadcell/lmb_a. html.

Google Scholar