Study on the Z-Source Inverter with Low Voltage Stress

Article Preview

Abstract:

This paper proposed a kind of low voltage stress Z-source inverter topology. In the topology, the inductors of Z-source can be connected alternatively in parallel during the time of shoot-through and in series during the other time. Thus the network can obtain a high boost factor with a small shoot-through duty ratio and can decrease the voltage stress across the switch divices greatly. The principle of the topology was analyzed in detail and the simulation experiments was made as well. Simulation results verified the validity of the topology.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2020-2025

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Peng Fangzheng. Z-source inverter[J]. IEEE Trans. on Industry Applications, 2003, 39(2): 504-510.

Google Scholar

[2] Peng Fangzheng,Fang Xupeng,Gu Bin,et al.Z-source converter [J].Transactions of China Electrotechnical Society, 2004, 19(2):47-51.(in Chinese).

Google Scholar

[3] Peng F Z,Joseph A,Wang J,et al.Z-source Inverter for motor drives[J].IEEE Transactions on Power Electronics,2005,20(4): 857-863.

DOI: 10.1109/tpel.2005.850938

Google Scholar

[4] Peng F Z,Shen Miaosen,Qian Zhaoming.Maximum boost control of the Z-source inverter[J]. IEEE Transactions on Power Electronics,2006,20(4):833-838.

DOI: 10.1109/tpel.2005.850927

Google Scholar

[5] Shen Miaosen,Wang J,Joseph A,et al.Maximum constant boost control of the Z-source inverter[J].IEEE Transactions on Industry applications,2006,42(3):770-778.

DOI: 10.1109/tia.2006.872927

Google Scholar

[6] Miaosen Shen, Jin Wang, Fang Zheng Peng. Constant Boost Control of the Z-Source Inverter to Minimize Current Ripple and Voltage Stress[J]. IEEE Transaction on Industry applications, 2006, 42(3): 770-775.

DOI: 10.1109/tia.2006.872927

Google Scholar