Abstract:

Algorithm and realization of the arrester in cable line in online-monitoring system based on the resistive current detection using phase search is discussed in this paper. The effectiveness of this method is manifested by the actual experience in the engineering construction.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2289-2293

Citation:

Online since:

October 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhao Pu, etc.: Construction of Province-district-county Integrated Electricity Grid Equipment Maintenance Management System [J]. Automation of Electric Power Systems, 2009, 33(21): 97-100.

Google Scholar

[2] Ren Kaiyin, etc.: Research and Application of the Date Processing Technique in Date Exchange System [J]. Electric Power Information Technology, 2009, 7(1): 44-48.

Google Scholar

[3] Ma Qianzhou: Realization and Application of the Unified and Structure Date in Power Grid [J]. Electric Power Information Technology, 2009, 7(3): 42-44.

Google Scholar

[4] Zhao Pu, etc.: Construction of Province-district-county Integrated Electricity Grid Equipment Maintenance Management System [J]. Automation of Electric Power Systems, 2009, 33(21): 97-100.

Google Scholar

[5] Ren Kaiyin, etc.: Research and Application of the Date Processing Technique in Date Exchange System [J]. Electric Power Information Technology, 2009, 7(1): 44-48.

Google Scholar

[6] Ma Qianzhou: Realization and Application of the Unified and Structure Date in Power Grid [J]. Electric Power Information Technology, 2009, 7 (3): 42-44.

Google Scholar

[7] Heinrich, C. and Hinrichsen, V.: Diagnostics and Monitoring of Metal-Oxide Surge Arresters in High-Voltage Networks—Comparison of Existing and Newly Developed Procedures IEEE Trans. on Power Delivery . 2001, 16(1): 138-143.

DOI: 10.1109/61.905619

Google Scholar

[8] Karawita, C and Raghuveer, M.R.: Leakage current based assessment of degradation of MOSA using an alternative technique[C]. CEIDP Conf. 2005, 5: 199 – 201.

DOI: 10.1109/ceidp.2005.1560655

Google Scholar

[9] Christodoulou, C.A. and Avgerinos, M. V, et al.: Measurement of the resistive leakage current in surge arresters under artificial rain test and impulse voltage subjection[J]. Science, Measurement & Technology, IET . 2009, 3 (3): 256-262.

DOI: 10.1049/iet-smt:20080123

Google Scholar

[10] Abdul-Malek, Z, et al. : Field experience on surge arrester condition monitoring - Modified Shifted Current Method[C]. UPE Conf. 2010, 9: 1 - 5.

DOI: 10.1109/ichve.2010.5640787

Google Scholar

[11] Fu Zhongjun: Application of Zero-crossing Method and Harmonic Analysis Method in Accurate Measurement of the Fundamental Wave of MOA Resistive Current [J]. Surge Arrester. 2004 (2): 34-37.

Google Scholar

[12] Zhu Baosen, etc.: An Extracting Method Based on Analysis of Current Magnitude at Zero-point of Voltage for Resistive Current of MOA [J]. Proceedings of the Chinese Society for Electrical Engineering. 2012, 32 (2): 165-172.

Google Scholar