Numerical Investigation on the Effect of Down Stand Structure in Fire Compartment on Smoke Contamination Atrium Upper Balconies

Article Preview

Abstract:

Atrium is gaining popularity in the modern societies because of its special attraction. However, during fire incident it causes significant risk due to its open spaces between floors. In atriums smoke can move easily to upper floors through these open spaces and causes smoke contamination of the atrium upper floors. Moreover, presence of down stand structure at the fire compartment opening is required in any shop in atrium shopping mall to display the trade name of the shop. This study investigated the effect of down stand structure on smoke contamination of upper balconies of an atrium by using Fire Dynamic Simulator, CFD software. A correlation that predict the smoke contamination occurrence in the presence of fire compartment down stand structure is developed. The results shows that down stand structure resulted in increasing the effect of smoke contamination in upper floors of an atrium.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

480-484

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] W.M.N.I. Ibrahim, International, Fire Safety: The way forward and Challenges ahead, Fire Conference and Exhibition Malaysia, (2012).

Google Scholar

[2] J.H. Klote, J.A. Milke, Principles of Smoke Management, American Society of Heating, Refrigerating and Air-conditioning Engineers. Atlanta, (2002).

Google Scholar

[3] H.P. Morgan, B.K. Ghosh, G. Garrad, R. Pamlitschka, J.C.D. Smedt and L.R. Schoonbaert, Design Methodologies for Smoke and Heat Exhaust Ventilation. Building Research Establishment. Watford, UK, (1999).

Google Scholar

[4] F. Tan, Physical Scale Modeling of Smoke Contamination in Upper Balconies by a Balcony Spill Plume in an Atrium, Fire Engineering Research Report, University of Canterbury, New Zealand, (2009).

DOI: 10.1177/0734904109350151

Google Scholar

[5] C.L. Ho, Simulation of smoke contamination in upper balcony by a channelled balcony spill plume in an atrium. Fire Engineering Research Report, University of Canterbury, New Zealand, (2010).

DOI: 10.1002/fam.2150

Google Scholar

[6] R. Harrison, Smoke Control in Atrium Buildings: A Study of the Thermal Spill Plume, Fire Engineering Research Report, University of Canterbury, New Zealand, (2004).

Google Scholar

[7] R. Harrison, Entrainment of air into thermal spill plumes, PhD thesis, University of Canterbury, (2009).

Google Scholar