Optimal Design of the Data Center Environmental Temperature Monitoring

Article Preview

Abstract:

Traditional datacenter temperature monitoring method is to install some temperature sensors which are unable to cover all areas completely, so there are some problems about local hot spot. The method is aiming to find out the position of potential hazard which may exist in the data center on the basis of data center thermal environment evaluation method and characteristics of air distribution. By applying this method into the wireless sensor network monitoring system, it brings a meaningful improvement of the monitoring system.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2810-2815

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Fu Yuda. Research and design of wireless monitoring system of computer room[D]. Heilongjiang university, (2010).

Google Scholar

[2] Yang ping, Xiao ying, Jian qifei, Luo xuewei, Liu wenfei. The airflow characteristics and air conditioning cooling capacity allocation scheme of communication room[J]. Journal of South China University of Technology(Natural Science Edition), 2009, 37(11): 107-111.

Google Scholar

[3] Sharma P K, Bash C E, Patel C D. Dimensionless parameters for evaluation of thermal design and performance of large scale data centers[C]/Proceedings of the American Institute of Aeronautics and Astronautics(AIAA), St. Louis, MO, 2002, Paper AIAA-2002-3091.

DOI: 10.2514/6.2002-3091

Google Scholar

[4] Bash C E, Patel C D, Sharma P K. Efficient thermal management of data centers immediate and long term research needs[J]. Int. J. Heating, Ventilating, Air Conditioning and Refrigeration Research, 2003, 9(2): 137-152.

DOI: 10.1080/10789669.2003.10391061

Google Scholar

[5] Magunus K. Herrlin. Airflow and Cooling Performance of Data Centers: Two performance Metrics[J]. ASHRAE Transactions, 2008, 114(2): 182-187.

Google Scholar

[6] Tian hao, Li zhen, Liu xiaohua, Qian xiaodong. Study on the evaluation index data center thermal environment[J]. Journal of refrigeration, 2012, 33(5): 5-9.

Google Scholar

[7] Jennic official website [EB/OL]. http: /www. jennic. com/products/wireless_microcontrollers/jn5121.

Google Scholar

[8] Sensirion official website [EB/OL]. http: /www. sensirion. com/en/pdf/product_information/Datasheet-humidity-sensor-SHT7x. pdf.

Google Scholar

[9] Wang jinggang, Kang ligai, Liujie, Paolingling. Feasibility analysis of cooling IDC using outdoor cold source[J]. Heating Ventilation Air Conditioning, 2009, 39(2): 128-132.

DOI: 10.1109/ccdc.2009.5191830

Google Scholar