How to Improve the Reliability of Wind Turbines

Article Preview

Abstract:

According to the failure of wind turbines in operation, the failure cause and phenomenon of wind turbines is analyzed, combined with the reliability of wind turbine subsystems, measures aiming at cooperation parts and purchased parts are proposed, the reliability of the whole wind turbines is improved in a certain extent. At the same time, condition monitoring system can carry through the early detecting and diagnosing to potential component failure maintain. Besides, automatic lubrication system can realize accurate and timeliness lubrication, also can reduce maintenance workload, preserve correct lubrication and smooth running of all parts.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

771-775

Citation:

Online since:

June 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yiqiang W, Yazhou J, Weiwei J. Early failure analysis of machining centers: A case study [J]. Reliability Engineering and System Safety, 2001, 72(1): 91 - 97.

DOI: 10.1016/s0951-8320(00)00100-9

Google Scholar

[2] Wankun Liu, Zhiying Zhang, Yinfeng Li. Wind energy and wind power generation technology[M]. Bei Jing: Chemical Industry Press.

Google Scholar

[3] Ke Wang, Shige Liu, Shufang Wang. Research on the reliability design theory for MW scale wind turbine generator system [J]. China-energy-conservation, 2005(11): 21-24.

Google Scholar

[4] Shuyong Chen, Huizhu Dai, Xiaomin Bai. Reliability model of wind power plants and its application [J]. Proceedings of the CSEE, 2000, 20(3): 26-28.

DOI: 10.1109/icpst.1998.729277

Google Scholar

[5] G.M. Joselin Herbert, S. Iniyan, E. Sreevalsan, et al. Areview of wind energy technologies [J]. Renewable and Sustainable Energy Reviews, 2007, 11(6) : 1117- 1145.

DOI: 10.1016/j.rser.2005.08.004

Google Scholar

[6] M. Martins, A. Perdana, P. Ledesma, et al. Validation of fixed speed wind turbine dynamic models with measured data [J]. Renewable Energy, 2007, 32(8) : 1301- 1316.

DOI: 10.1016/j.renene.2006.06.007

Google Scholar

[7] Kaiyan Xie, Genzhong Wu, Donghao Pan. Design of medium-sized wind power generator control system reliability [J]. Journal of mechanical & electrical engineering, 1998(1): 48-49.

Google Scholar

[8] H. SÊker, H. Seifert ; DEWI Preventive Load Monitoring and Condition Monitoring - How to Reach the Scheduled Service Life without Financial Damage DEWI Magazin Nr. 23 , August (2003).

Google Scholar

[9] Yi Shi, Xinwei Cui, Chunlan Li. The Application of On-line Monitor System on Anemo-electric Generator.

Google Scholar

[10] Xing Yin, Dianhong Wang, Cheng Liu. Based on AVR on-line monitor system design and realization[J]. Feng Ji Ji Shu, 2007(4): 74-76.

Google Scholar

[11] Ruichuang Wang, Wuhong Lin. Research on on-line monitoring and fault diagnosis of wind turbine[J]. East China Electric Power, 2009, 37(1): 190-193.

Google Scholar

[12] Dongxiang Jiang, Liangyou Hong, Qiang Huang, Yongshan Ding. Condition Monitoring and Fault Diagnostic Techniques for Wind Turbine [J]. Power System and Clean Energy, 2008(09).

Google Scholar

[13] Braam RademakersL, Verbruggen T W. CONMOW; Condition Monitoring for Offshore Wind Farms[C]/ECN-RX-03-036. Petten, June (2003).

Google Scholar

[14] Yuan Xie, Yuxian Qiang. Condition Monitoring of Large-scale Megawatt Wind Turbines [J]. Journal of Shang Hai Dian Ji University, 2009, 12(4): 271-275.

Google Scholar