Research on Remote Wireless Pulse Monitoring and Analysis System

Article Preview

Abstract:

ECG signal contains a large number of health information of human body, the accurate measurement of ECG signal have important significance on the prevention and treatment of cardiovascular disease (CVD). The existing pulse detection instruments cannot meet the needs of today's society in terms of portability and real-time, especially for the elderly with CVD, it almost has nothing effect on real-time monitoring. Therefore, a wrist pulse real-time monitoring system is designed in this dissertation, which can make real-time detection and record the pulse information, and do short-term heart rate variability (HRV) analysis to the pulse information gained, to react and sent a distress signal with multilevel alarm mechanism quickly when the patient is sick, trying the best to ensure the safety of patients' life. Experimental results show that the hardware circuit of this system is stable and reliable, and pulse analysis algorithm has a good consistency with a small amount of data, this system can be applied to CVD monitoring in modern family.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1550-1554

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Li Shanzhu. The research of pulse wave real-time anaiysis technology and the design of dragnostic system. Master's degree thesis of Hangzhou Dianzi University. 2011: 4~5.

Google Scholar

[2] World Health Organization (WHO) Global Observatory for eHealth: New horizons for health through mobile technologies. Geneva, 2011: 1~12.

Google Scholar

[3] U. Varshney. A framework for supporting emergency messages in wireless patient monitoring. Decision Support Systems. 2008, 45: 981~996.

DOI: 10.1016/j.dss.2008.03.006

Google Scholar

[4] T. Ma, Y. T. Zhang. A correlation study on the variabilities in pulse transit time, blood pressure, and head rate recorded simultaneously from healthy subjects. Conf Proc IEEE Eng Med boil Soc. 2005, 1: 99~105.

DOI: 10.1109/iembs.2005.1616585

Google Scholar

[5] C. H. Kyoung, D. Y. Kim, S. J. Jung. A recording of the Radial pulse wave system using photo plethysmogram. SICE Annual Conference 2005 in Okayama. 2005, 11(2): 8~10.

Google Scholar

[6] R. N. Michael, D. B. Gail, M. Stuart. Advances in Medical Devices and Medical Electronics. Proceedings of the IEEE. 2012, (100): 1537~1550.

Google Scholar

[7] J. Ohga, T. Takei, N. Moriyama. Wideband Piezoelectric Rectangular Loudspeakers Using A Tuck shaped PVDF bimorph. IEEE Transactions on Dielectrics and Electrical Insulation. 2010, 17(4): 1074~1078.

DOI: 10.1109/tdei.2010.5539677

Google Scholar

[8] S. Fabien, O. B. Abdel, C. C. Jean. Generalized higher-order nonlinear energy operators. Journal of the Optical Society of America. 2007, 24: 3717~3727.

Google Scholar

[9] M. Costa, A. L. Goldberger, C. K. Peng. Multiscale Entropy Analysis of Biological Signals. Physical Review E. 2005, 71(2): 021906-1~021906-3.

Google Scholar