Seismic Consolidation of ’60s Pilotis R.C. Building for Social Housings with SCC-Steel Shear Walls

Article Preview

Abstract:

The reinforcement of a r.c. building for social housing has been achieved by using Steel-Concrete Composite (SCC) walls at the ground floor, preceded by temporary brick pillars for structural deficiency to vertical loads, due to the poor load capacity of the r.c. columns. The SCC walls have been realized first by placing steel columns on both sides of the existing pillars and, after removal of the temporary brick piers, by merging the steel columns in the cast of the new walls. The top of the walls has been connected to the upper floor in order to ensure the diffusion of the seismic forces. Foundations have been reinforced to support the seismic base shear.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1937-1942

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Arabzadeh, A., Soltani, M., Ayazi, A. Experimental investigation of composite shear walls under shear loadings, Thin-Walled Structures, 49(7), 842-854, (2011).

DOI: 10.1016/j.tws.2011.02.009

Google Scholar

[2] Dan, D., Fabian A., Stoian V. Theoretical and experimental study on composite steel–concrete shear walls with vertical steel encased profiles, Journal of Constructional Steel Research, 67(5), 800-813, (2011).

DOI: 10.1016/j.jcsr.2010.12.013

Google Scholar

[3] Hajjar J.F. Composite steel and concrete structural systems for seismic engineering, Journal of Constructional Steel Research, 58(5-8), 703-723, (2002).

DOI: 10.1016/s0143-974x(01)00093-1

Google Scholar

[4] Zhao, Q., Astaneh-Asl, A. Cyclic Behavior of Traditional and Innovative Composite Shear Walls, Journal of Structural Engineering - ASCE, 130(2), 271-284, (2004).

DOI: 10.1061/(asce)0733-9445(2004)130:2(271)

Google Scholar

[5] Giresini L, Gioeli A, Sassu M (2013). Seismic reinforcement of a r. c. building with external steel frameworks: the case of the primary school XXV April of Arcola (Italy). Advanced Materials Research, vol. 834-836, pp.697-700, ISSN: 1662-8985.

DOI: 10.4028/www.scientific.net/amr.834-836.697

Google Scholar

[6] Komoto, H., Kojima T., Mase Y., Suzuki K., Wen X. Case study on the soft-first-story buildings strengthened by confined concrete columns, 13th World Conference on Earthquake Engineering, August 1-6, Vancouver, B. C., Canada, (2004).

Google Scholar

[7] Mezzi, M., Parducci A., Preservation of Existing Soft-First-Story Configurations by Improving the Seismic Performance, 3rd Int. Spec. Conf on The Conceptual Approach to Structural Design. August, Singapore, (2005).

Google Scholar

[8] CEN/TC 250 Structural Eurocodes. EN 1992-1-1: 2005, Eurocode 2: Design of concrete structures – Part 1-1: General rules and rules for buildings.

DOI: 10.1680/dgte2docs.31050

Google Scholar

[9] Ministero delle Infrastrutture. Decreto Ministeriale 14/01/2008 pubblicato su S.O. n. 30 alla G. U 04/02/2008, n. 29. Approvazione delle nuove norme tecniche per le costruzioni. NTC2008. (in Italian).

Google Scholar

[10] CEN/TC 250 Structural Eurocodes. EN 1998-3: 2005, Eurocode 8: Design of structures for earthquake resistance – Part 3: Assessment and retrofitting of buildings.

Google Scholar