Flow Calibration and Error Analysis of Dual-Axis Tracking Trough Solar Collector System

Article Preview

Abstract:

In this paper, a dual-axis tracking trough solar collector system is established, and used to measure and calibrate flow rate at different conditions by using the ultrasonic flow meter and mass flow meter, providing important reference for follow-up experimental study. With the changing of the medium’s temperature and the rotation speed variation of the pump, the two flow meters were used to work together to measure the accurate flow measurements, obtaining the measurement error of the mass flow meter. After that, the reason of error and methods used to reduce the error are analyzed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

262-265

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C. Ling. Development and application of new type of flowmeter [J]. Transducer and Microsystem Technologies. 26 (6), 8-11. (2007).

Google Scholar

[2] J.G. Drenthen, Boer G. The manufacturing of ultrasonic gas flowmeter [J]. Flow measurements and Instrumentation, 12 : 89- 99 . ( 2001).

DOI: 10.1016/s0955-5986(01)00003-6

Google Scholar

[3] N. Roosnek. Novel digital signal processing techniques for ultrasonic gas flow measurements[ J] . Flow Measurements and Instrumentation, 11: 89 – 99, (2000).

DOI: 10.1016/s0955-5986(00)00008-x

Google Scholar

[4] M. Takamoto, H. Ishikawa,K. Shimizu, eta. New measurement method for very low liquid flow rates using ultrasound [J]. Flow Measurements and Instrumentation , 8: 267- 273, (2001).

DOI: 10.1016/s0955-5986(01)00023-1

Google Scholar

[5] A. Tewodros. Design of an electromagnetic flow meter for insulating liquids [J]. Measurement Science and Technology , 10( 8) : 755-758, (1999).

Google Scholar

[6] Zhang X Z . The 2D analysis for the virtual current distribution in an electromagnetic flow meter with a bubble at its different axis positions [J]. Measurement Science and Technology, 9: 1-5, (1998).

DOI: 10.1088/0957-0233/9/9/019

Google Scholar

[7] Michalski, Andrze. Dry calibration procedure of electromagnetic. Flow meter for open channels [J]. IEEE Transactions on Instrumentation and Measurement, 49: 434- 438, (2000).

DOI: 10.1109/19.843092

Google Scholar

[8] C X, Yu, K J, Xu, J J, Liu. An improvement of signal processing method based on DFT for Coriolis mass flowmeter[J]. Journal of Hefei University of Technology. 23(6): 935-943, (2000).

Google Scholar

[9] K J, Xu, C X, Yu, J H, Su. Development of excitation circuit for Coriolics mass flowmeters [J]. Journal of Hefei University of Technology. 23(1): 37-40, (2000).

Google Scholar

[10] A. Tewodros. Design of an electromagnetic flow meter for insulating liquids [J]. Measurement Science and Technology, 10( 8) : 755- 758, (1999).

Google Scholar

[11] Michalski, Andrze Dry calibration procedure of electromagnetic. Flow meter for open channels [ J ] . I EEE T ran sactions on Instrumentation and Measurement, 49: 434-438, (2000).

DOI: 10.1109/19.843092

Google Scholar

[12] RR, Zhai, Y Zhu, Y P, Yang . etc. Exergetic and Parametric Study of a Solar Aided Coal-Fired Power Plant [J]. Entropy. 15, 1014-1034. (2013).

DOI: 10.3390/e15031014

Google Scholar