Research on the HIL Platform of Photovoltaic Grid Connected System

Article Preview

Abstract:

In order to analysis the characteristics of grid connected photovoltaic system, this paper proposes a Hardware-in-Loop (HIL) real time testing platform based on RT-LAB. The main circuit real time model is built in the RT-LAB, then connect the real time model with a DSP digital controller to achieve the double closed-loop control. And the HIL platform is used to analysis the low voltage ride through (LVRT) technology of grid connected photovoltaic under the of situation power grid fault. The experimental results validate the effectiveness and correctness of the model and the LVRT control strategy.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

266-269

Citation:

Online since:

October 2014

Keywords:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W. REN: IEEE Trans on Power Delivery, Vol. 26(2011)No. 2, p.1221.

Google Scholar

[2] Q. Sun,H. Lin and Z.Y. Wang: Electronic Measurement Technology, Vol. 32(2009)No. 1, p.24.

Google Scholar

[3] Z.G. Lu,J.Y. Chai and X.H. Wang: Proceedings of the CSEE, Vol. 23(2003)No. 4, p.119.

Google Scholar

[4] D.X. Wei: Power Electronics Specialists Conference(Aachen, Germany, June 20-25, 2004) Vol. 3, p. (1950).

Google Scholar

[5] J.H. Yuan: Research on Micro-Grid Based on Distributed Photovoltaic Generation Systems(Ph.D., Shandong University, China 2012), p.23.

Google Scholar