Reason Analysis and Treatment Measures of Cracks in a Masonry Structure

Abstract:

Article Preview

This paper analyses some kinds of fissures in walls of a multi-story masonry buildings with additional floor transformation, and puts up several methods for dealing with the fissures. Through the spot inspection and computation analysis, the reason of crack producing is put forward. Because the ring beams only built in the first and the top floor, and precast floor slabs used in the building, the overall structure rigidity is poor. The internal longitudinal wall is strengthened by steel tension bar, simultaneously; an addition shallow submersion foundation is added on the original foundation. After the reinforcement processing, the structure is complete until now.

Info:

Periodical:

Edited by:

Dongye Sun, Wen-Pei Sung and Ran Chen

Pages:

4610-4613

DOI:

10.4028/www.scientific.net/AMM.71-78.4610

Citation:

H. Y. Tang "Reason Analysis and Treatment Measures of Cracks in a Masonry Structure", Applied Mechanics and Materials, Vols. 71-78, pp. 4610-4613, 2011

Online since:

July 2011

Authors:

Export:

Price:

$35.00