Calculative Method for Critical Condition of Fire Liftoff Caused by Man-Made Interfering Jet Flow
Abstract:
Based on the critical condition of fire liftoff about exhaust flow, the critical condition of fire liftoff caused by man-made interfering jet flow on the laminar flow condition was researched. The calculative formula for critical condition of fire liftoff caused by man-made interfering jet flow on the laminar flow condition was acquired. And the experiments were designed to validate the formula. The results show that the formula was accord with the experiments. It could be used for engineering application.