p.111
p.118
p.124
p.130
p.138
p.146
p.153
p.160
p.168
Fire Safeguards of “Plastbau” Construction
Abstract:
There are exposed the results of resistance testing on effects of fire in interfloor construction and wall panel made according to “plastbau” system technology out of expandable polystyrene, when they are protected by mortar extension as an insulator. The applied testing method is prescribed by standard form EN 13501-2. Based on testing results, there is affirmed that interfloor construction fulfills resistance criteria on effects of fire of 180 min, and wall panel fulfills resistance criteria on effects of fire of 60 min, when it is protected by mortar extension as an insulator..