Behaviour of Composite Column of Cold-Formed Steel Section with Web-Stiffener Integrated with Ferrocement Jacket

Article Preview

Abstract:

Cold-formed steel (CFS) is known as slender or class 4 section due to high ratio of web-to-thickness ratio. The compressive strength of this type of section is usually very low as it tends to fail due to distortion and warping before reaching the actual compressive strength. The aim of this study is to determine the ultimate capacity of build-up lipped CFS assembled with ferrocement jacket where web-stiffener is provided as the proposed composite column (CFFCC) is under axial compression load. Nine specimens of composite columns were prepared and tested. The main parameters varied in the CFFCC columns are column height, cold-formed steel thickness and influence of ferrocement jacket and web-stiffener. There are three different heights of the CFFCC composite column namely 2000mm, 3000mm and 4000mm used in this study. All CFFCC columns were tested under axial load where a thick steel plate is used to evenly distribute the applied load. The results show the effect of providing both the ferrocement jacket to increase the confinement effect and the web stiffener to provide sufficient lateral support to the column web. A significant increase in both the strength and the ductility of the specimens under axial loading has been recorded. The strength capacity of CFFCC has been improved by about 178% greater than that of bare steel column. Also it is found that, axial load capacity of CFS-ferrocement jacket composite columns (CFFCC) were increased with the increase in thickness of CFS. The use of web-stiffener has improved the axial load capacity of the column but not that significant.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

533-538

Citation:

Online since:

April 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] A.S. Saadon, Experimental and Theoretical Investigation of PVC Concrete composite Columns, Ph.D. Thesis, University of Basrah, (2010).

Google Scholar

[2] K.F. Sarsam, I.A. Al-Shaarbaf and M.S. Shuber, Behavior of Short Reinforced Porcelinite Concrete Columns Under Concentric Loads, Eng. Technol. J. 27 (6) (2009) 1219-1234.

Google Scholar

[3] W.W. Yu, Cold-Formed Steel Design, John Wiley & Sons, New York, (2000).

Google Scholar

[4] B.C. Gourley, C. Tort, J.F. Hajjar and P.H. Schiller, A synopsis of studies of the monotonic and cyclic behaviour of concrete filled steel tube beam-columns, Struct. Eng. Report No. ST-01-4. Minneapolis, Minnesota Department of Civil Engineering, Institute of Technology, University of Minnesota, 55455, (2001).

Google Scholar

[5] B.W. Schafer, Distortional Buckling of Cold-Formed Steel Columns, Final Report to the American Iron and Steel Institute, Washington, D.C. (2000).

Google Scholar

[6] K.P. Rathish, T. Oshima, Sh. Mikami and T. Yamazaki, Studies on RC and Ferrocement Jacketed Columns Subjected to Simulated Seismic Loading, Asian J. Civil Eng. Building and Housing, 2 (8) (2007) 215-255.

Google Scholar

[7] A.H.M.M. Billah, Seismic performance evaluation of multi column bridge bent retrofitted with different alternative, Okanagan, The University of British Columbia, Master Appl. Sci. (2011) 176.

Google Scholar

[8] S. EFNARC, Guidelines for self-compacting concrete. London, UK: Association House, (2002) 32-34.

Google Scholar

[9] A. ANSI, AISC 360-05, Specification for Structural Steel Buildings, American Institute of Steel Construction, Inc, Chicago, IL, (2005).

Google Scholar