Finite Element Modelling of Innovative Precast Cold-Formed Steel Ferrocement as Composite Beam

Article Preview

Abstract:

This paper describes Finite Element Modeling (FEM) of a composite beam comprised of cold formed steel section and concrete slab designed as ferrocement. Software (ANSYS, version 11) was adopted to carry out the modeling of the proposed composite beam. Experimental tests were also been carried out for three simple supported composite beams. The proposed innovative precast composite beam specimens of cold-formed steel lipped channel sections (CFS) connected with ferrocement slab were tested till failure, under two point loads positioned atquarter length of the span from support. The results showed that close agreement was observed between the FEM and experimental results for ultimate loads and load-deflection responses.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

539-543

Citation:

Online since:

April 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] W.K. Yu, K.F. Chung and M.F. Wong, Analysis of bolted moment connections in cold-formed steel beam-column sub-frames. J. Constr. Steel Res. 61 (2005) 1332–1352.

DOI: 10.1016/j.jcsr.2005.03.001

Google Scholar

[2] R. Abdullah, M.M. Tahir and M.H. Osman, Performance of CFS of Box-Section as Composite Beam, in 6th International Conference on Steel and Space Structures. Singapore, (1999) 365-370.

Google Scholar

[3] K.M.A. Hossain, Experimental and theoretical behavior of thin walled composite filled beams, Electron. J. Struct. Eng. 3 (2003) 117-139.

Google Scholar

[4] A. Hanaor, Test of composite beams with cold-formed section, J. Constr. Steel Res. 54 (2) (2000) 245-264.

Google Scholar

[5] S. Nakamura, Bending behavior of composite girders with cold formed steel U section, J. Struct. Eng. 128 (9) (2002) 1169-1176.

DOI: 10.1061/(asce)0733-9445(2002)128:9(1169)

Google Scholar

[6] S.N. Shaari and E. Ismail, Promoting the use of industrialised building systems and modular coordination in the Malaysian construction industry, Board of Engineers Malaysia. Bulletin Ingenieur, (2003) 6–8.

Google Scholar

[7] G.J. Hancock, Review article: Cold-formed steel structures, J. Constr. Steel Res. 59 (2003) 473-487.

Google Scholar

[8] J.M. Irwan, A.H. Hanizah and I. Azmi, Test of shear transfer enhancement in symmetric cold-formed steel–concrete composite beams, J. Constr. Steel Res. 65 (2009) 2087–(2098).

DOI: 10.1016/j.jcsr.2009.07.008

Google Scholar

[9] A.E. Naaman, Ferrocement and Laminated Cementitious Composites, Techno Press 3000, An Arbor, Michigan, USA, (2000).

Google Scholar

[10] C.Z. Kam, A.B.H. Kueh, P.N. Shek, C.S. Tan and M.M. Tahir, Flexural performance of laminated composite plates with diagonally perturbed localized delamination, Adv. Sci. Lett. 15 (1) (2012) 5-8.

DOI: 10.1166/asl.2012.4042

Google Scholar

[11] A.B.H. Kueh, W.W. She, P.N. Shek, C.S. Tan and M. M. Tahir, Maximum local termal effects carpet polt for symmetric laminated composite plate, Adv. Mater. Res. 250-253 (2011) 1271-1274.

DOI: 10.4028/www.scientific.net/amr.250-253.3748

Google Scholar

[12] C.S. Tan, Y.H. Lee, Y.L. Lee, S. Mohammad, A. Sulaiman, M.M. Tahir, P.N. Shek, Numerical Simulation of cold-formed steel top-seat flange cleat connection, J. Tech. (Science and Engineering), 61 (3) (2013) 63-71.

DOI: 10.11113/jt.v61.1769

Google Scholar

[13] Y.H. Lee, C.S. Tan, Y.L. Lee, M.M. Tahir, S.M. Poi and N. Shek, Numerical modeling of stiffness and strength behavior of top-seat flange-cleat connection for cold-formed double channel section, Appl. Mech. Mater. 284-287 (2013) 1426-1430.

DOI: 10.4028/www.scientific.net/amm.284-287.1426

Google Scholar

[14] L.Y. Huei, T.C. Siang, M.M. Tahir, S. Mohamad, Numerical modeling and validation of light gauges steel top-seat flange-cleat connection, J. Vibroeng. 14 (3) (2012) 1104.

Google Scholar

[15] M.M. Tahir, I. Juki, L.H. Yong, S. Mohammad, S.P. Ngian, Finite Element Analysis of Flush End-Plate Connection connected to column web, Int. J. Steel Struct. 11 (3) (2011) 247-258.

DOI: 10.1007/s13296-011-3001-3

Google Scholar