Research and Governance on Catalyst Abrasion for Selective Catalytic Reduction (SCR) System in Power Plant Boiler

Article Preview

Abstract:

This paper presents a research on the problem of catalyst failure in a selective catalytic reduction (SCR) system. The preliminary analysis indicates that the catalyst failure is caused by abrasion. For this, firstly, the mechanism of abrasion is analyzed through a field experiment. Secondly, according to the results from the field experiment, a scheme is put forward to optimize the flow field. Finally, the application results show that the uniformity of fly ash distribution in the flue gas are improved prominently, the reliability of the SCR system is enhanced at the same time.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

125-131

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Yang Dong,Xu Hong.Discussion on the application of the SCR technology in coal- fired power plants[J].Electric Power Environmental Protection,2007(1).

Google Scholar

[2] Zhao Yi,Zhu Hongtao,et al.Research on the SCR technology in coal-fired power plants[J].Electric Power Environmental Protection,2009(1).

Google Scholar

[3] Lu Jiayi,Lu Xiaofeng,et al.The recent application of De-NOx SCR catalysts[J].Power System Engineering,2008(1).

Google Scholar