Analysis on the Pressure Fluctuation of a 660MW Supercritical Boiler

Article Preview

Abstract:

This paper presents the analysis on the periodic fluctuation of pressure in flue and air system of a 660MW supercritical boiler, firing high sulfur coal. The analysis shows that the fluctuation is resulted from a blockage in its air pre-heater, especially in winter. Just as the temperature of flue gas lower than its acid dew point, corrosion occurs and induces the blockage furthermore. This paper exhibits a typical case in boiler firing high sulfur coal.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

110-115

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Wu dongli, Wang jie, et al. Analysis and countermeasures on the clogged air presented of a 660MW denitrification unit[J]. Zhejiang Electric Power, 2014(3).

Google Scholar

[2] Lu Shunxin, Dai Rong, et al. Analysis and Prevention on the air preheater plug fouling of a 660MW Supercritical Boiler[J]. Hunan Electric Power, 2012(2).

Google Scholar

[3] Yang Tie, Liu Dafeng, Non-typical combustion problems caused by blockage in air preheater and solutions[J]. Boiler Manufacturing, 2009(1).

Google Scholar