Research on Water Pump Isolation Parameters Based on Power Flow
Abstract:
Vibration parameter of water pump is studied by power flow theory, water pump isolation vibration system can be simplified a single-deck isolation system model, by using electric-machine (E-F) analog method, the curves of foundation speed amplitude and power flow are drawn, the results show that the inertia block has clearly reduced the vibration power flow and speed amplitude, increasing the mass of inertia block can decrease the first peak point and make the first peak point moving toward the low frequency direction, increasing surface density of the basement can decrease input power flow and the vibration of basement.