Carbon Fiber Cloth in Structural Engineering Application

Article Preview

Abstract:

The frame beam end uses the carbon fiber cloth restraint, then uses the steel stranded wire assembly,which is a new assembly architecture structure. This thesis studies deeply the crack development characteristics, failure pattern, hysteresis curve and the displacement ductility of prestressed precast reinforced concrete frame, by analyzing one prestressed precast reinforced concrete frame under low reversed cyclic load test. We build a model using finite element analysis software to the test piece model analysis, the analysis result agree well with the experimental results. Experimental studies indicate that assembly of prestressed reinforced concrete frame structure has a good seismic performance. This prestressed precast reinforced concrete frame is a new kind of structural system complying with the development of architectural industrialization, which is worthy of popularization and application in the earthquake area.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 160-162)

Pages:

146-150

Citation:

Online since:

November 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] DONG Ting-feng. Experimental and Theoretical Research on Seismic Performance of Precast Prestressed Concrete Frame Structure with Unbonded Post-tensioned Tendons[D]. Beijing University of Technology. 2006, 10. 3.

Google Scholar

[2] HAN Jianqiang, LI Zhenbao. Assembly of New Connections Form Concrete Frame Structure[J]. Journal of Industrial Construction. 2009, 39(11): 100-10.

Google Scholar

[3] LIU Meng.Analysis and Experimental Study on Behavior of Prestress Assembling Concrete Beam-column Connections Added Passive Energy Dissipation Devices[D].Beijing University of Technology. 2008, 10.

Google Scholar

[4] WANG Dong-yan. Research of Seismic Performance and Reinforcement Performance of Precast Prestressed Concrete Connections with Unbonded Post-Tensioned Tendons[D]. Beijing University of Technology. 2008, 06.

Google Scholar

[5] LI Zhen-bao,DONG Ting-feng et al.Study on Seismic Performances of Hybrid Precast Concrete Beam-to-column Connections[J] . Journal of Beijing University of Technology.2006, 32(10):895-900. (in Chinese).

Google Scholar

[6] DONG Ting-feng,LI Zhen-bao,ZHOU Xi-yuan et al.An experimental study on seismic performances of precast prestressed concrete beam-to-column connections with unbonded tendons[J]. Journal of Beijing University of Technology.2006, 32(2):144-148. (in Chinese).

Google Scholar

[7] WANG Dong-yan,LI Zhen-bao.Experimental Research on Unbonded Post-tensioned Precast Concrete Beams[J] . Journal of Industrial Construction. 2008,38(2):31-34.

Google Scholar

[8] QIU Fa-wei,QIAN Jia-ru,CHEN Zhi-peng.Anti-seismic test method[M] . Beijing:Science Press, (2000).