Method of Compensation Control for Shaking Table

Article Preview

Abstract:

This paper presents the defects existing in shaking table control including the overshoot of displacement under low-middle frequency input using three variable parameter controls, the narrow bandwidth resulting from the performance of servo-valve and low accuracy of seismic wave reproduction because of specimen and table interaction. The effects of these factors on the stability and control accuracy of shaking table are discussed, and then the reasons of these problems existing are analyzed. The aim of this paper is to improve the stability and control accuracy of shaking table, thus, some corresponding strategies for compensation control are proposed. And a series of shaking table tests with one-story frame and two-story frame for verifying the validity of compensation control algorithm are performed.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 199-200)

Pages:

1397-1404

Citation:

Online since:

February 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Blondet M, Esparza C. Analysis of shaking table-structure interaction effects during seismic simulation tests [J]. Earthquake Engineering & Structural Dynamics, 1988, 16: 473-490.

DOI: 10.1002/eqe.4290160402

Google Scholar

[2] Trombetti TL . Analytical modeling of a shaking table system. Department of Civil Engineering, Rice University, Houston, Texas, USA. 1997: 29-129.

Google Scholar

[3] Conte JP, Trombetti TL. Linear dynamic modeling of a uni-axial servo-hydraulic shaking table system [J]. Earthquake Engineering & Structural Dynamics, 2000, 29(9): 1375-1404.

DOI: 10.1002/1096-9845(200009)29:9<1375::aid-eqe975>3.0.co;2-3

Google Scholar

[4] Trombetti TL, Conte JP. Shaking table dynamics: results from a test-analysis comparison study [J]. Journal of Earthquake Engineering, 2002, 6(4): 513-551.

DOI: 10.1080/13632460209350428

Google Scholar

[5] Symans M , Twitchell B. System identification of a uniaxial seismic simulator Proc. 12th Engineering Mechanics Conference. American Society of Civil Engineers, Reston, VA, 1998, pp.758-761.

Google Scholar

[6] Zhenbao Li,Zhenyun Tang,Jinbao Ji. Overshoot Modification of Shaking Table TVC Algorithm . Journal of Vibration and Shock,2010, 9(10): 221-225(In Chinese).

Google Scholar

[7] Haohua Huang. Design and Application Technology of Shaking Table [M]. Beijing, Seismological Press, Beijing, 2008(in Chinese).

Google Scholar

[8] Liu Lianshan Tian Jixiong. Identification and Verification of Transfer Function of Electro Hydraulic Servo-Valve. Journal of Dalian Maritime University, 1984, 10(03): 42-49. (In Chinese).

Google Scholar

[9] Zhenbao Li,Zhenyun Tang, Haohua Huang ect. Performance Improvement of Servo Valve and Its Application in Shaking Table. Journal of Wuhan University of Technology, 2010, 9(36): 194-198+279(In Chinese).

Google Scholar

[10] Zhenbao Li, Zhenyun Tang, Daxing Zhou ect. Effects on the Earthquake Simulation Caused by theCharacteristics of the Specimen in the Shaking Table Tests-Part 1: Effects on the Stability of the System. Journal of Beijing University of Technology 2010, (8): 1091-1098(In Chinese).

Google Scholar