Research on Microcomputer Relay Protection Anti-Interference of 500kV Transmission Line in MATLAB

Article Preview

Abstract:

This paper established a 500kV microcomputer protection model with EFT/B generator. The generator was built based on the mechanism of arc forming and distinguishing when cutting off the no-load transmission line. The according parameters were set by the arc estimating formula and test data. The simulations shows that the traditional disincentive measure is limited for high voltage line and the arithmetic is still sensitive to the disturbance and made the relay set false operation. A comprehensive measure is put forward and tested by the microcomputer protection arithmetic.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 204-210)

Pages:

1346-1350

Citation:

Online since:

February 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Fengying MA. EFT/B interference transmission model and method of anti-interference in a coal mine monitoring substation[J]. Mining Science and Technology (China), Volume 20, Issue 3, May 2010, Pages 391-394.

DOI: 10.1016/s1674-5264(09)60213-1

Google Scholar

[2] Zhao Xiaoming, Wu Jun, Yu Zhihui. Frequency-spectra analysis of electrical fast transient/burst and an instance of microprocessor-based protection abnormally reboot caused by EFT/B[J]. Relay, 2006, 34(17): 8-12.

Google Scholar

[3] Wang Yufeng, Zou Jiyan, Liao Minfu. Suppressing Electrical Fast Transient Burst for Power Supply of Microprocessor Protection Device [J]. High Voltage Apparatus, 2010, 46(3): 10-14.

Google Scholar

[4] Gong Qingwu, Lai Wenqing, Wu Su. Digital Simulation Comparision of Transmission Line Fault Location with EMTP and MATLAB[J]. North China Electric Power, 2001, 10: 31-34.

Google Scholar

[5] Yang Liqin, Yang Xiaoping, Liang Zhenfeng, ect. Relay Protection Simulation System Based on EMTP and MATLAB[J]. Power System and Clean Energy, 2009, 25(11): 33-36.

Google Scholar

[6] Zhang Lixia, Kang Wei, Wu Zian, et al. Study on the Forming Mechanism and safeguard procedures of Electrical Fast Transient Burst[C]. CSIST 2010, Hang Zhou, China, Dec. 4-6.

DOI: 10.1109/icise.2010.5689644

Google Scholar

[7] Yao Lixiao; Yao Jinxiong; An Yuan. Fault Location Simulation For High Voltage Power Transmission Line Based On MATLAB/SIMULINK[J]. Power System Technology, 2005, 29(10): 53-56.

Google Scholar