Output Prediction Method Based on Model and its Application in Power Systems

Article Preview

Abstract:

An output prediction method based on state space model is proposed to overcome the poor reliability of the prediction method that does not use system model. The open-loop state observer is established based on the system state space model. Then the output prediction model is built in which the prediction error is used as input and a correction module is also contained. The module is used to correct the prediction error, and then the current predicted output can be obtained by the model from the delayed output. At last, a wide-area damping controller in power systems based on output prediction is designed to verify the effectiveness of the method.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 219-220)

Pages:

986-989

Citation:

Online since:

March 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Xie Xiaorong; Xiao Jinyu; Tong Luyuan; Han Yingduo. Inter-area damping control of interconnected power systems using wide-area measurements [J]. Automation of Electric Power Systems, 2004, vol. 28, no. 2, pp.37-40(in Chinese).

DOI: 10.1109/drpt.2004.1338497

Google Scholar

[2] Xue Yusheng, XU Wei, Zhaoyang Dong, WAN Qiulan. A Review of Wide Area Measurement System and Wide Area Control System [J]. Automation of Electric Power Systems, 2007, vol. 31, no. 15, pp.1-6(in Chinese).

Google Scholar

[3] Gongyou Tang, Zhongqing Yu, Zhaohui Sun. Design of state predictive observer and predictive controller for systems with time-delay, [J], Control and Decision, Mar 2003, vol.18, no.2: 207-209.

Google Scholar

[4] Luo Ke, Liu Yutian, Ye Hua. Wide-Area Damping Controller Based on Model Prediction and Sliding Mode Control. The 8th World Congress on Intelligent Control and Automation(WCICA2010), July 7-9, 2010, Jinan, China, pp.3728-3731.

DOI: 10.1109/wcica.2010.5555092

Google Scholar

[5] Xie Xiaorong; Cui Wenjin; Tang Yiliang; Han Yingduo. Direct iterative algorithm to solve the extended Levine-Athans equations [J]. Journal of Tsinghua University(Science and Technology), 2001, vol. 41, no. 1, pp.1-4(in Chinese).

Google Scholar

[6] Kundur P. Power System stability and control [M]. New York: McGraw-Hill, 1994, pp.813-816.

Google Scholar

[7] Balarko, Rajat Majumder, Bikash C. Pal. Wide-Area Measurement-Based Stabilizing Control of Power System Considering Signal Transmission Delay [J]. IEEE Transactions on Power Systems, November 2004, vol. 19, no. 4: 971-(1979).

DOI: 10.1109/tpwrs.2004.835669

Google Scholar