Failure Analysis of Drill Collar Box Fracture

Article Preview

Abstract:

One 203mm drill collar failed infrequently just after 200h of pure drilling time. This paper gives a systematic analysis in consideration of both material quality and loading condition on drill strings. Measurement and inspection were performed on configuration, chemical composition, mechanical performance, metallograghy and micro-fractograghy. It’s thought that the drill collar failure accident was premature fatigue failure accident. Failure reason is the mechanical damage caused by improper manufacture process in the root of thread. Under the effect of fluctuating stress, fatigue cracks originated from mechanical damage position and grew rapidly. When cracks propagated through the wall thickness, drill collar fractured.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 295-297)

Pages:

2129-2132

Citation:

Online since:

July 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] SY/T5144 Drill Collar[S]. Oil and Gas Industry Standards of China.

Google Scholar

[2] API Spec 7-1 Specification for Rotary Drill Stem Elements[S]. American Petroleum Institute.

Google Scholar

[3] Helin LI, Pingquan Li, Yaorong Feng. Petroleum drill string failure analysis and prevention [M]. Beijing: Petroleum Industry Press , 1999: 122-137.

Google Scholar

[4] Chinese mechanical engineering society of heat Treatment. Heat treatment quality control and testing (Heat treatment handbook volume 4) [M]. Beijing: Mechanical Industry Press, 2008: 27.