Research and Development the Method of Transformer Winding Deformation Fault Diagnosis Based on FRA

Article Preview

Abstract:

For the purpose of enhance the accuracy and sensitivity of FRA of transformer winding deformation fault diagnose, this paper made several improvements on the traditional FRA. Regarding the signal source's insufficiency, we changed the impulse replaces the sine frequency sweep signal. The test results showed: after the improvement, the test cycle reduces and the signal frequency response range is broader. We also used the FFT and EMD method to improvement the analysis of frequency response curves, this increased the analysis accuracy and diagnose sensitivity, find the fault characteristic. This study can be used on the development of transformer winding fault diagnosis, detection and test methods.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 301-303)

Pages:

742-747

Citation:

Online since:

July 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Vandermaar A J, Srivastava K D. Review of Condition Assessmerit of Power Transformers in Service[J]. IEEE Electrical Insulation Magazine, Vol. 18-6(2002), pp.12-25.

DOI: 10.1109/mei.2002.1161455

Google Scholar

[2] CHENG Sheng, CHEN San-yun, MA Qiang et al. Case Analysis of Over Standard of Low Voltage Short Circuit Impedance in Transformer Test [J]. High Voltage Apparatus, 2009, 45(2): 108-111.

Google Scholar

[3] OU Xiao-bo, GU Chao-ming, JI Sheng-chang et al. Research of Transformer Winding Deformation Fault Diagnose by FRA and LVI [J]. High-Technology & Industrialization, 2009(1): pp.123-126.

Google Scholar

[4] DICK E P, ERVEN C C. Transformer diagnostic testing by frequency response analysis [J]. IEEE Transactions on Power Apparatus and Systems, Vol. 97-6(1978) , pp.2144-2153.

DOI: 10.1109/tpas.1978.354718

Google Scholar

[5] HE Ping, WEN Xi-shan. Survey of Frequency Response Analysis on Winding Deformation of Transformers[J]. HIGH VOLTAGE ENGINEERING, Vol. 32-5(2006) , pp.37-41.

Google Scholar

[6] HAN Ai-zhi, LIU Sheng-yu, ZENG Ding-wen et al. Simple Method to Judge Deformation of Transformer Windings[J]. TRANSFORMER, Vol. 4(2003) , pp.8-12.

Google Scholar

[7] PU Xiao-yu. Research and application of winding deformation spotting in transformer based on frequency response method[J]. DISTRIBUTION & UTILIZATION, Vol. 24-1(2007) , pp.43-45.

Google Scholar

[8] YU Yun-fei. Research the Virtual System of Transformer Winding Deformation Fault Diagnose [D]. Yang Zhou: Yang Zhou University, 2010. 03.

Google Scholar

[9] P.R. C National Development and Reform Commission. Electric Power Industry Standard of People's Republic of China DL/T911—2004[S]. 2004, pp.2-3.

Google Scholar

[10] Rahman M A A, Hashim H, Ghosh P S, Frequency response analysis of a power transformer [C]. Australasian Universities Power Engineering Conference. Christchurch, New Zealand,(2003).

Google Scholar

[11] CUI Wen, WANG FU-zeng, LIU Bo et al. Analyzing LEMP and Protection[C]. Proceeding on International Lightning Conference in China (ILCC), 2006, pp.233-234.

Google Scholar

[12] Huang N E, Shen Z, Long S R. The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis[M]. Proc. Roy. Vol. 454, (1998).

Google Scholar