Study on the Pretreatment of LAS Wastewater by UV/Fenton Oxidation Technology

Article Preview

Abstract:

Abstract. Fenton and UV/Fenton oxidation technology were used to treat LAS wastewater. Experimental results showed that in the conditions of pH=6.0、Fe2+=7mM、H2O2/Fe2+=10:1, LAS removal efficiency was higher. Under the same conditions, for the removal efficiency of LAS and COD, UV/Fenton method is higher than Fenton method. After the treatment of UV/Fenton, the B/C value of raw water increased from 0.28 to 0.49, and can meet the requirements of biological process as followed.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 347-353)

Pages:

1860-1864

Citation:

Online since:

October 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chen Li,Zhou Xingquan,Wu Jiangdong: Industrial Water Treatment, 2003,23(10):12-16[In Chinese]

Google Scholar

[2] Xie Guangyan,Liang Kaiwen: Environmental Protection, 1997,(5):10-12[In Chinese]

Google Scholar

[3] Fu Sixian:Environmental Science and Technology, 1988(40):28-30[In Chinese]

Google Scholar

[4] Chen Jiamei,Lu Jiao:Beijing Agriculture Science, 1994,12(2):36-39[In Chinese]

Google Scholar

[5] Atsushi Miyagi, Mitsutoshi Nakajlma:Water Research, 2002, 36(15): 3889-3897

Google Scholar

[6] Rosen M J. A :Anal Chem, 1963, 35(11): 2074-2077

Google Scholar

[7] Liu Zhenyu Wang Dong,He Zhijun: Environmental Engineering, 1998,163:24~27 [In Chinese]

Google Scholar

[8] Bum Gun Kwon, et al:Wat. Res, 1999,33 (9): 2110-2118

Google Scholar

[9] Michele E, et al: Chemosphere, 41 (2000): 409-417

Google Scholar