Causes Analysis and Treatment Measures for Excess SiO2 Content in a 300MW Unit Boiler Water

Article Preview

Abstract:

According to the characteristics of silicon in water, analysis is implemented for the excess SiO2 content in a 300MW unit boiler water. Serious excess SiO2 content in the economizer inlet water and boiler water is caused by high-pressure heater leakage. In addition, SiO2 content increases with the raising feedwater temperature, because colloidal silicon solubility increases with the raising feedwater temperature. Colloidal silicon in water is induced by condenser tiny leakage. High-pressure heater plugging must be handled. Improving activated charcoal filters washing and boiler blow-off frequency can be used to reduce the impact of colloidal silicon on boiler and ensure safe operation of the boiler

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 361-363)

Pages:

1859-1862

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] M. S. Bhatt: Energy Conversion and Management Vol. 47 (2006), P. 1247

Google Scholar

[2] W. H. W, H. Yang, H. Ma, X. P. Yao, X. Wang: Journal of Shanghai University of Electric Power Vol. 18 (1), P. 9

Google Scholar

[3] Information on http://chinayzb.blog.163.com/blog/static/15565392010101285541378

Google Scholar

[4] J. A. Redondo, F. Lanari: Desalination Vol. 113(1997), P. 309

Google Scholar