Calculation and Analysis of Electrical Field in Valve Side Winding of Converter Transformer

Article Preview

Abstract:

The numerical calculation model with compound insulation of transient electrical field is established. The types of voltage applied on the valve side winding of the converter transformer are complicated and the insulation is more prominent. So the simplied calculation model of the valve side winding of the converter transformer is established. The distribution characteristics of electrical field of the valve side winding of the converter transformer is analyzed and electric field in different electrical conductivity and permittivity are calculated under AC high voltage, DC high voltage, AC superimposed DC voltage, polarity reversal voltage. Under all kinds of high voltages, the maximum electric field strength is calculated and analyzed. Some important influence factors for electrical field distribution are also discussed in this paper.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Pages:

4865-4870

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Bowles J P, Burtnyk V, Diemond C C, et al. AC-DC Economics and alternatives-1987. panel session report, IEEE. Trans. Power Deliv. , 1990, , 5(4): 1956-(1976).

DOI: 10.1109/61.103692

Google Scholar

[2] K.C. Wen, Y. B, Zhou, J . Fu J et al. A Calculation Method and Some Features of Transient Field under Polarity Reversal Voltage in HVDC Insulation, . IEEE Tran On power delivery, Jan 1993, vol. 8, No, 1: 223-230.

DOI: 10.1109/61.180340

Google Scholar

[3] WANG Chun-ling, LI Jian-hua. The Computation and analysis on electric field in valve side winding polarity reverser of converter Transformer,. [J]. Transformer, 2005, 42(2): 11-14.

Google Scholar

[4] WEN Kai-cheng, WANG Rui-zhen. Effectiveness of dielectric tests on value side of converter transformer for insulation examination(part1), [J]. Transformer, 1997, 34(11): 10-14.

Google Scholar

[5] WEN Kai-cheng, WANG Rui-zhen. Effectiveness of dielectric tests on value side of converter transformer for insulation examination(part1), [J]. Transformer, 1997, 34(11): 10-14.

Google Scholar

[6] Ohshima I, Motegi S, Honda M, et al. HVDC breakdown of transformer oil and the effect of space charge on it., IEEE. Trans. Power Appar. &Syst., 1983, 102(7): 2208-2215.

DOI: 10.1109/tpas.1983.318209

Google Scholar