Experimental Investigation on Air-Solid Two-Phase Mixture Discharge under AC Voltage

Article Preview

Abstract:

Multi-phase mixture (MPM) discharge has the common characteristics of randomness with air but more complex. How about the statistical rule of MPM discharge This is not only a fundamental problem for discharge research, but it has its own strong applied and practical characteristics. The air-solid two-phase mixtures(ASTPM) are employed to study and carry out some experiments for investigating the development and breakdown of MPM discharge under AC voltage. The results from experimental data show that the AC breakdown voltage and corona-inception voltage will drop when the solid particles are added to the discharge chamber with different permittivity and volume fraction. And there is no influence in gas flow and the corona current.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 383-390)

Pages:

4955-4961

Citation:

Online since:

November 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yashima M, Fujinami and Takuma T, Breakdown characteristics of gases mixed with tetrachlorethylene mist under nearly uniform fields, IEEE Trans. on Electr. Insul. 1990, 25(2) : 371-379.

DOI: 10.1109/14.52387

Google Scholar

[2] Tardiveau P and Marode E, Point-to-plane discharge dynamics in the presence of dielectric droplets,J. Phys. D: Appl. Phys. 2003 , 36: 1204-1211.

DOI: 10.1088/0022-3727/36/10/309

Google Scholar

[3] Yajima S, Lijina N, Sone M, Mitsui H, Effect of Mist Formation in Vapor-Mist on Partial Discharge, Annual Report - Conference on Electrical Insulation and Dielectric Phenomena , Oct, 1990, 319-724.

DOI: 10.1109/ceidp.1990.201361

Google Scholar

[4] Goshima H, Suzuki T, Hayakawa N, Hikita M and Okubo H, Dielectric breakdown characteristics of cryogenic nitrogen gas above liquid nitrogen, IEEE Trans. on Dielectrics and Electr. Insul. 1994 , 1(3): 538- 544.

DOI: 10.1109/94.300298

Google Scholar

[5] Qureshi M I, Al-Arainy A A, Malik N H, Performance of rod-rod gaps in the presence of dust particles under lightning impulses, IEEE Transactions on Power delivery, 1991, 6(2): 706-714.

DOI: 10.1109/61.131130

Google Scholar

[6] Al-Arainy A A, Malik N H, Qureshi M I, Influence of sand/dust contamination on the breakdown of asymmetrical air gaps under lightning impulses, IEEE Transactions on Electrical Insulation, 1992, 27(2): 193-206.

DOI: 10.1109/14.135591

Google Scholar

[7] Al-Arainy A A, Malik N H, Qureshi M I, Influence of sand/dusi contamination on the breakdown of asymmetrical air gaps under switch impulses, IEEE Transactions on Electrical Insulation, 1994, 1(2): 303-3.

DOI: 10.1109/94.300263

Google Scholar