Abstract:

With the development of functional and structural materials, increasing interests have been shown in the field of biomaterials with a negative Poisson’s ratio (auxetic), which exhibit the unusual property of becoming thinner when compressed. This unusual property makes it potentially a synthetic replacement biomaterial with adequate mechanical property and wear resistance. In this study, the potential of applying the auxetic ultra-high molecular weight polyethylene (UHMWPE) for the artificial hip joint was discussed. The contact mechanics characteristics in artificial hip joint replacement under different Poisson's ratios of -1<μ≤0.5 were investigated and compared using the finite element method. The results show that Poisson’s ratio had great effect on the contact mechanics in artificial hip joint replacement. Therefore, the future work should focus on tailoring an auxetic UHMWPE with a suitable Poisson’s ratio for artificial hip joint replacements.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 399-401)

Pages:

1559-1563

Citation:

Online since:

November 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] R. Lakes: Science Vol. 235 (1987), p.1038

Google Scholar

[2] K.E. Evans, M. Nkansah, I.J. Hutchison and S.C. Rogers: Nature Vol. 353 (1991), p.124

Google Scholar

[3] D.R. Veronda and R.A. Westmann: J. Biomech. Vol. 3 (1970), p.111

Google Scholar

[4] L.M. Frohlich, M. Labarbera and W. P. Stevens: J. Zool. Lond. Vol. 232 (1994), p.231

Google Scholar

[5] C. Lees, J.E.V. Vincent and J.E. Hillerton: Biomed. Mater. Eng. Vol. 1 (1991), p.19

Google Scholar

[6] J.L. Williams and J.L. Lewis: J. Biomech. Eng. Vol. 104 (1982), p.5

Google Scholar

[7] M.A. Fortes: Mater. Sci. Eng. A Vol. 122 (1989), p.227

Google Scholar

[8] G.E. Stavroulakis: Phys. Stat. Sol. (b) Vol. 242 (2005), p.710

Google Scholar

[9] K.E. Evans and A. Alderson: Advanced Mater. Vol. 12 (2000), p.617

Google Scholar

[10] A. Alderson and K.L Alderson: Proc. Instn Mech. Engrs, Part G, J. Aerospace Eng. Vol. 221 (2007), p.565

Google Scholar

[11] Z.M. Jin, S.M. Heng, H.W. Ng and D.D. Auger: Proc. Instn Mech. Engrs, Part H, J. of Eng. in Medicine, 1999; 213: 317–27.

Google Scholar

[12] Z.M. Jin, D. Dowson and J.A Fisher: Med. Eng. Phys. Vol. 16 (1994), p.398

Google Scholar

[13] D.L. Bartel, A.H. Burstein, M.D. Toda and D.L. Edwards: J. Biomech. Eng. Vol. 107 (1985), p.193

Google Scholar

[14] L. Kang, A.L. Galvin, J. Fisher and Z.M. Jin: J. Biomech. Vol. 42 (2009), p.912

Google Scholar

[15] D. Mazzucco and M. Spector: Wear Vol. 254 (2003), p.514

Google Scholar