The Voltage Output Characteristics of New 24-Pulse Rectification System under Unbalanced Source Voltage

Article Preview

Abstract:

The traditional 6-pulse high-power rectifier has defects such as large harmonic content and low power factor in application. The 24-pulse rectification system based on autotransformer can restrain the harmonics and improve power factor effectively. This paper derivate the input current and output voltage’s characteristics of 24-pulse rectification system under balanced grid. At the same time, the author simulate and analysis various impacts of different situations of unbalanced grid on these two characteristics on the basic of real grid ,which has an important guiding significance on the application of the 24-pulse rectification system.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

3820-3825

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Thomas G.W. The Evolution of Power Electronics[J]. IEEE Trans. on power electronics, 2000, 15(3): 439-446.

Google Scholar

[2] Fang Changshi, Fang Joshua. Study on the double connection of modified bridge rectifier with power factor improvement[J]. IEEE Trans. IA2006, 126(11): l479-1485.

DOI: 10.1541/ieejias.126.1479

Google Scholar

[3] Fukalda S, Hiei I. Auxiliary supply assisted input current harmonic reduction in 12-pulse thyristor rectifiers[C]. International Conference on Power Electronics and Drives Systems, 2005(2): l481-l486.

DOI: 10.1109/peds.2005.1619807

Google Scholar

[4] Farrer W. Significant source harmonic reduction achieved using direct parallel connection of two 6-pulse converters[J]. IEE Proc Electr. Power App1, 2006, 153(2): 167-l76.

DOI: 10.1049/ip-epa:20045213

Google Scholar

[5] Chivite-Zabalza F J, Forsyth A J, Trainer D R. A simple, passive 24-pulse AC-DC converter with inherent load balancing [J] IEEE Trans. Power Electro, 2006, 21(2): 430-439.

DOI: 10.1109/tpel.2005.869754

Google Scholar

[6] Girish R. Kamath, Bruce Runyan, Richard Wood. A compact autotransformer based 12-pulse rectifier circuit[J]. The 27th Annual Conference of the IEEE, 2001(2): 1344-1349.

DOI: 10.1109/iecon.2001.975977

Google Scholar

[7] Syafri Martinius, Burhanuddin Halimi. A transformer connection for multipulse rectifier applications[J]. International Conference on Power System Technology, 2002 (2): 1021-1024.

DOI: 10.1109/icpst.2002.1047554

Google Scholar

[8] Conference on Power System Technology, 2002 (2): 1021-1024.

Google Scholar