Analysis of Harmonic Detection of APF&SVG

Article Preview

Abstract:

This paper reviews the harmonic current detection algorithm of APF&SVG. And the new different research of each detection method is introduced. The advantage and disadvantage of each methods is also analyzed. It has provided some references to the electric current detection algorithm choice for the design of the APF and SVG.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 516-517)

Pages:

1683-1687

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Akagi H, Kanazawa Y, Nabae A, Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components. IEEE IA, Vol. IA-20, NO. 3, MAY/JUYN 1984: 625~630.

DOI: 10.1109/tia.1984.4504460

Google Scholar

[2] Sasaki H, Machida T. A new method to eliminate ac harmonic currents by magnetic compensation consideration on basic design. IEEE Transactions on app. And syst., 1971,90(5):2009-2019.

DOI: 10.1109/tpas.1971.292996

Google Scholar

[3] Akagi H, Nabae A, Atoh S, Control Strategy of Active Power Filters Using Multiple Voltage-Source PWM Converters. IEEE IA, Vol.IA-22, NO. 3, MAY/JUYN 1986: p.460~465.

DOI: 10.1109/tia.1986.4504743

Google Scholar

[4] Hui Wang, Qingmin Li, Minglei Wu, Lin Mu, Preparation of Investigation on a New Algorithm for Instantaneous Reactive and Harmonic Currents detection Applied to Intensively Nonlinear Loads.IEEE, 1-4244-0726-5/06,2006 P2557~2562.

DOI: 10.1109/icit.2006.372593

Google Scholar

[5] Sun Zhihong, Cui Jingxiu. A Comparative Study of Two Different Detecting Approaches of Active Power Filter A Comparative Study of Two Different Detecting Approaches of Active Power Filter [J]. THE WORLD OF INVERTERS, 2008,(01):p.89~92.

Google Scholar

[6] Shen Aibing. Study on the Detection Approaches of Harmonic Currents and Simulation for the Active Power Filters [D].North China Electronic Power University , 2006.

Google Scholar

[7] Yang Jun, Wang Zhaoan, Qiu Guanyuan. Study on detection method for fundamental positive-sequence active current under unsymmetrical and distorted three-phase system voltage [J]. Journal of Xi'an Jiaotong University, 1996,(03):p.94~100.

Google Scholar

[8] SHI Zhengwei, WEI Sihai, WU Bing, HUANG Yongli. Research on the Current Detection Algorithm for Reactive and Harmonic of Active Power Filters [D]. IEEE 978-1-4244-4813-5/10, 2010.

Google Scholar

[9] Zhang Qian, Wang Binbin, Zhu Haiyun Ma Haibo, "Alterable Integral Control Algorithm for Shunt Active Power Filter". Proceedings of the 2011 International Conference on Advanced Mechatronic Systems, p.576~579,Zhengzhou, China, August 11-13, 2011.

Google Scholar

[10] Jingshuang Shen, Chuanwen Jiang, Yujiao Liu and Weijun Liu, "Energy saving analysis of TSC&APF Integrated Device" Advanced Materials Research Vols. 347-353 (2012) pp.2559-2563.

DOI: 10.4028/www.scientific.net/amr.347-353.2559

Google Scholar

[11] Meng Li, Heping Ma, The detection of active power filter, IEEE 978-1-4244-9439-2/11, 2011, p.745~748.

Google Scholar