Failure Analysis on Fracture of a 3-1/2″ P110SS Tubing

Article Preview

Abstract:

The tubing, as a key ingredient in the well development, worked always under very complex stress and corrosion conditions, the failure of the tubing could cause huge losses. In this paper, a fractured 3-1/2″ P110SS tubing was analyzed through physical and chemical properties testing, SEM, EDS, and XRD method. The results showed that the failure of the tubing was belong to hydrogen sulfide stress corrosion cracking. The tubing material could not pass the SSC test, it was inappropriate to use in well contained high hydrogen sulfide.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 524-527)

Pages:

1412-1417

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Q/SY-TGRC2-2009, Recommended practice for tubing and casing of carbon and low alloy steels for use in H2S-containing environments.2010.CNPC Tubuler goods reaserch institute.

Google Scholar

[2] API RP 5C5, Recommended Practice on Procedures for Testing Casing and Tubing Connections. Third edition, 2003. Washington DC: API.

Google Scholar

[3] Jun Hu,Fei Liu,Guangxu Cheng,et al: Annals of Nuclear Energy, 38(2011), p.1901.

Google Scholar

[4] G.Pantazopoulos,A.Vazdirvanidis,G.Tsinopoulos:Engineering Failure Analysis 18(2011), p.650.

Google Scholar

[5] Sun Zhi,Jiang Li,Ying Pengzhan,in:Failure Analysis.China machine press,Bei Jing,2009, p.125.