Study on the Measurement Method and Safety Design of Ultrasonic Cleaning Equipment
Abstract:
To the question that it was hard to measure and verify the safety design rationality of the performance parameters for the ultrasonic cleaning machine, the destructive effect mechanism of the ultrasonic cleaning was analyzed. It was indicated that the cleaning power and time were the two main factors for damaging the insulating layer of the cleaning objects. The measuring technology was presented by aluminum foil, and it analyzed feasibility and an area assessment method for the measurement method by aluminum foil. The practical long time test of the motor demonstrated that the measurement method by aluminum foil can provide safety design data support and experimental verification to the performance parameters design of the ultrasonic cleaning machine.