T91 High Temperature Reheater Piping Leakage Analysis

Article Preview

Abstract:

Now T91steel is more and more used in power plant pipe components. The leakage of high temperature reheater pipe was analyzed after surveying the leaking site, checking material composition and observing the microstructure of related materials. We found that a large number of dust at the bottom of the pipe stopped the expansion of high temperature reheater tube rows, the connecting structure between pipes through fins was irrational, and welding fins process was substandard. Cracks were originated from fin-side weld, and extended to the pipe wall , which finally led to a leakage.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 605-607)

Pages:

300-303

Citation:

Online since:

December 2012

Keywords:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J.F. Mullen and R.Clark. Kahe: Power,1995,(1),41.

Google Scholar

[2] G.Eggeler:Int. J. Pres. Ves & Piping,1994,(60),273

Google Scholar

[3] M.Regev and S.Berger: Welding J.,1996,(8),2615.

Google Scholar

[4] Z.Zhang and A.W. Marshall:in Proc.Inter. Conf.Integrity of High-Temperature Welds,London, England,1998,77.

Google Scholar

[5] R.K. Singh Ramon: Metall. Mater. Trans. A.,29A(2),577.

Google Scholar

[6] B.J. Brett, D.J. Abson and R.L. Jones:in Proc. Inter. Conf.Integrity ofHigh-Temperature Welds,London, England,1998,53.

Google Scholar

[7] Qi LI, GB 5310-2008 ,Seamless steel tubes and pipes for high pressure boiler,2008.

Google Scholar

[8] Yan LUAN, GB1220-2007,Stainless steel bars,2007.

Google Scholar

[9] Yaojun LI,DL/T 884-2004,Power plant metallography inspection and assessment guideline, 2004.

Google Scholar