Direct Torque Control for Brushless Doubly-Fed Machine Based on Fuzzy-PI Regulator

Article Preview

Abstract:

The inverter switch state is based on the torque error and the stator flux amplitude error in the hysteretic controller which is adopted on the traditional direct torque control for the brushless doubly-fed machine, in this way, current and flux are distorted that results torque ripple in low speed range, even more influents control effect of the whole system. According to this problem, a new direct torque control method with fuzzy-PI regulator for the brushless doubly-fed machine is presented in this paper, applying the fuzzy theory to design controller parameters. The simulation results show that the method is effective to improve the dynamic characteristics of the motor, reduce the torque ripple, improve the speed and the torque control precision, and expand the direct torque control system of speed range.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 614-615)

Pages:

1185-1189

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] R Spee, AK Wallace, HK Laue. Performance simulation of Brushless doubly-fed adjustable speed drives. IEEE Industrial Applications Society Annual Meeting, San Diego, 1989, 738-743

DOI: 10.1109/ias.1989.96730

Google Scholar

[2] X. x. Zhou, A. l. Zhang. Torque ripple minimization strategy for the direct torque control of brushless doubly-fed machine [J]. Electric machines and control, 2006, 10 (6): 571-575

DOI: 10.5772/intechopen.89979

Google Scholar

[3] S. d. Huang, Y. Wei, Y. J. Lin. Fuzzy-Based Power Factor Control For Brushless Doubly-Fed Machines[C]. In: WCICA Paper, 2001: 587-591

Google Scholar

[4] Z. k. Shao. Genetic algorithms-based fuzzy neural network sliding model control for doubly-fed machine[J]. International Conference on Computer and Communication Technologies in Agriculture Engineering, 2010, Vo.3, 467-475

DOI: 10.1109/cctae.2010.5544317

Google Scholar

[5] Farhad Barati, Hashem Oraee.Vector model utilization for nested-loop rotor brushless doubly-fed machine analysis, control and simulation[J]. IEEE1ST Power Electronic & Drive Systems & Technologies Conference, 2010: 295-301

DOI: 10.1109/pedstc.2010.5471806

Google Scholar

[6] H. X. Wu, L. Q. Fu. Inverter-brushless doubly-fed speed regulation system of the simulation [J]. Journal of Chinese electrical engineering, 2002, 22 (7) : 96-100

Google Scholar

[7] Z. W. Chen, H.X. Wu, H. Y. Shen. The brushless doubly-fed machine experts' adaptive PID control simulation study [J]. Journal of south China university of technology, 2003, 31 (12): 37-41

Google Scholar