Identification Model in Frying Oil Based on Interval Partial Least Squares Regression Analysis

Article Preview

Abstract:

As we known frying oil belongs to waste oils when it has been excessive used, long time usage also cause serious effect. This paper chooses dragon fish oil which was fried 10 times excessively. We can extract the characteristic in absorption peak (323.391.443nm) of spectral absorption value as the dependent variable. Then build the interval partial least square model, Through the MATLAB, we can extract the optimum interval is 5 and the best factor of wavelength range is 7. Prediction of correlation coefficient for R is 0.998. By the cross validation verification Q22=-0.3461<0.0975, we can get the establishment of PLS equation as Y1, Y2, Y3. The model which we build can predict the content situation of characteristic absorption peak in frying oil effectively.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 718-720)

Pages:

792-796

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Pan jian yu, Yin ping he, Yu han hao. The qualified Identification of old swill oil, frying oil and edible vegetable oil[J]. Food Science, 2003,24(8):27-29.

Google Scholar

[2] Van Gastel A, Mathur R, Roy VV etal. Ames muagenicity tests of repeatedly heated edible oils[J].Food Chen Toxicol,1984,22(5):403-407.

DOI: 10.1016/0278-6915(84)90371-5

Google Scholar

[3] Huang wei, Zhen jian jun, Xv jian hua. Rapid detection of waste oil security [J]. Journal of Shandong University of Science and Technology, Natural Science,2010,29(3):51-53.

Google Scholar

[4] Tan jun. Soft Sensor Modeling based on interval selection Partial Least Squares algorithm[J].Transducer and Micro-system Technologies,2007,26(5):57-63.

Google Scholar

[5] Wu gong huang, Shi xin yuan, Wu zhi sheng. Backward variable selection partial least squares method for near infrared spectroscopy correction model[J]. Mathematical Medicine. 2010, 3 (23):257-260.

Google Scholar

[6] Hirao M, Ogi H. EMATs for science and industry, noncontacting ultrasonic measurements [J].Boston; Kluwer Academic Publishers, 2003, 60(4):12-16.

Google Scholar

[7] B.Ames. Differential scanning calorimetric analysis for monitoring the oxidation of heated oils [J].science. 1983,221:177-184.

Google Scholar

[8] GB/T 2716-2005. Health standards of edible vegetable oil[S]. Beijing: Standards Press of China. 2005.

Google Scholar