Research on the Field Test Methods of Flow Rate and Water Level of Urban Drainage Pumping Stations

Article Preview

Abstract:

The flow rate and water level measure is one key work of the pumping station field test. And the reliable, applicable, economic and effective measurement method and instruments are the key decisive factors of the field test. The urban drainage pumping stations usually pump sewage, and its inlet structure and outlet structure generally use closed arrangement. These make the flow rate and water level measurement of the field test become complicated. Based on the characteristics of urban drainage pumping station, this paper analyzed the measurement methods of flow rate and water level parameters of the field test for urban drainage pumping station. In combination with a field test case for an urban drainage pumping station, this paper demonstrated how to choose the reliable, applicable, economic and effective measurement method to measure flow rate and water level parameters.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 718-720)

Pages:

903-907

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Li Jishan, Pumping Station Testing Technology[M], China Water Power Press, Beijing, 1987, pp.17-19.

Google Scholar

[2] SD140-85, Pumping Station Field Test Regulation[S], China Water Power Press, Beijing, 1985, pp.2-43.

Google Scholar

[3] TANG Zheng-jun, HUANG Ji-yan, QIU Bao-yun and FENG Xiao-li, Study on discharge measurement methods for large-sized pumps[J], China Rural Water and Hydropower, 2006, (12), pp.67-69.

Google Scholar

[4] YANG Hong-ling, MA Shu-sheng, ZHANG Jia-yi, FAN Ming-jing and ZHANG Feng, Comparative study on ultrasonic and velocity instrument in the flow measurement of open channel[J], Shandong Agricultural University(Natural Science Edition), Shandong, 2008, (2), pp.301-304.

Google Scholar

[5] Kawada Yuro, Komiya Chi, Flow Measurement Handbook [M], Metrology press, Beijing, 1982, pp.5-12.

Google Scholar

[6] DAI hong-xia, LI Bin, Problems of discharge measuring in spot test of pumping station[J], Water Conservancy Science and Technology and Economy, Beijing, 2005, (2), pp.106-108.

Google Scholar

[7] TANG Yue, YUAN Shou-qi, LI Hong, YUAN Jian-ping, Movement diagnosis and online measurement of the pump characteristics of sewage pumping Stations[J], China Rural Water and Hydropower, Beijing, 2008, (5), pp.94-96.

Google Scholar