Experimental Study on GAC-Sand Filter for Advanced Treatment in Drinking Water

Article Preview

Abstract:

A granular activated carbon sand dual media filter (GSF) was investigated as an advanced water treatment process of waterworks through the pilot test. The results show that the GSFs can remove organic matter in the water effectively instead of the sand filters. During the filtration,the effectiveness of CODMn elimination was effective, the average removal rate reached 48.2%. The average pH of the filtered water had dropped from 7.26 to 8.35, indicating that the alkaline environment is necessary for nitrifying bacteria to remain active. The ability of water treatment and quality could be raised and improve the chemical safety of the filtered water.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 726-731)

Pages:

3044-3047

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Dahab M,Sirigina S. Nitrate removal from water supplies using biodenitrification and GAC-sand filter systems. Water science and Technology, 1995, 30(9): 133~39

DOI: 10.2166/wst.1994.0462

Google Scholar

[2] Feng S, Xie S G, 2012. Ammonium removal pathways and microbial community in GAC-sand dual media filter in drinking water treatment. Journal of Environmental Sciences, 24(9) :1587–1593

DOI: 10.1016/s1001-0742(11)60965-0

Google Scholar

[3] Andersson A, Laurent P, Kihn A, Prevost M, Servais P, 2001.Impact of temperature on nitrification in biological activated carbon (BAC) filters used for drinking water treatment. Water Research, 35(12): 2923–2934.

DOI: 10.1016/s0043-1354(00)00579-0

Google Scholar

[4] Amy Gary L, Sierka Raymond A, James Bedessen, et al. Mo-lecular size distributions of dissolved organic matter. Journal AWWA,1992,6:67~75

DOI: 10.1002/j.1551-8833.1992.tb07377.x

Google Scholar

[5] Kim J, Kang B, 2008. DBPs removal in GAC filter-adsorber. Water Research, 42(1-2): 145–152.

DOI: 10.1016/j.watres.2007.07.040

Google Scholar

[6] Wang H X, Ho L, Lewis D M, Brookes J D, Newcombe G, 2007.Discriminating and assessing adsorption and biodegradation removal mechanisms during granular activated carbonfiltration of microcystin toxins. Water Research, 41(18):4262–4270.

DOI: 10.1016/j.watres.2007.05.057

Google Scholar

[7] Christian Volk, Kimberly Bell, 2000. Impact of enhanced and optimized coagulation on removal of organic matter and its biodegradable fraction in drinking water. Water Research,12(5):3247~3257

DOI: 10.1016/s0043-1354(00)00033-6

Google Scholar

[8] Bablon G P, Ventresque C, Aim R B. Developing a sand-GAC filter to achieve high-rate biological filtration. Journal American Water Works Association, 1988,80(12): 47~53

DOI: 10.1002/j.1551-8833.1988.tb03149.x

Google Scholar

[9] Liang C H, Chiang P C, 2007. Mathematical model of the nonsteady-state adsorption and biodegradation capacities of BAC filters. Journal of Hazardous Materials, 139(2): 316–322.

DOI: 10.1016/j.jhazmat.2006.06.033

Google Scholar

[10] Wataru,Tsujimoto,Haruo Kimura,Tomohiro Izuetal,1998. Membrane Filratration and Pretreatment by GAC. Desalination,119(6):323~326.

Google Scholar