Optimizing the Coupling of a Firebrand Generator to a Horizontal Wind Tunnel

Article Preview

Abstract:

Australia is considered as the most fire-prone country in the world. Spotting ignition by lofted firebrands is the main mechanism of fire spread. Many experimental studies have been conducted to evaluate the effect of the firebrand attacks on structures and to identify possible solutions. The experimental facility consists of a firebrand generator coupled to a wind tunnel. The wind speed in the firebrand generator is relatively low, in order to assure a quality continuous flow of glowing firebrands. On the contrary, the wind speed in the wind tunnel is high to duplicate actual firebrand attacks. Previous works show a highly turbulent region above the entrance of firebrands to the wind tunnel which is formed because of the velocity difference and penetration of firebrand entrance hose into the wind tunnel. The penetration is required to provide a uniform firebrand distribution along the height of the test section. In this computational work, the influence of the height of the entrance hose, its orientation respect to the tunnel and the distance between the coupling port and the test section are analyzed. The optimized results are presented and discussed for a variety of wind speeds within the wind tunnel and the firebrand generator.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 726-731)

Pages:

971-976

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P.A Cameron, Mitra B, Fitzgerald M, Scheinkestel CD, Stripp A, Batey C, Niggemeyer L, Truesdale M, Holman P, Mehra R, Wasiak J & Cleland H, "Black Saturday: the immediate impact of the February 2009 bushfires in Victoria'', Australia, volume 191 No 1, 2009.

DOI: 10.5694/j.1326-5377.2009.tb02666.x

Google Scholar

[2] J. Mitchell, "Wind enabled ember dousing''; Fire safety journal, 41, 2006, pp.444-458.

DOI: 10.1016/j.firesaf.2006.04.002

Google Scholar

[3] Manzello, S.L., John R. Shields, J.R., Cleary, T.G., Maranghides, A., Mell, W.E., Yang, J.C., Hayashi, Y., Nii, D. & Kurita, T. "On the development and characterization of a firebrand generator'', Fire safety journal, 43, 2008, pp.258-268.

DOI: 10.1016/j.firesaf.2007.10.001

Google Scholar

[4] S.L .Manzello,Park, S.H., Suzuki, S., Shields, J.R.& Hayashi, Y., "Experimental investigation of structure vulnerabilities to firebrand showers'', Fire safety journal, 46,2011 , pp.568-578.

DOI: 10.1016/j.firesaf.2011.09.003

Google Scholar

[5] S.Manzello,Suzuki, S. & Hayashi, Y., " Enabling the study of structure vulnerabilities to ignition from wind driven firebrand showers: A summary of experimental results'', Fire safety journal, 2012.

DOI: 10.1016/j.firesaf.2012.06.012

Google Scholar

[6] S.Suzuki, , Manzello, S.L. & Hayashi,Y., The size and mass distribution of firebrands collected from ignited building components exposed to wind, Fire safety journal, 2012.

DOI: 10.1016/j.proci.2012.06.061

Google Scholar

[7] R. Fox, Pritchard, P.J. & McDonald, A.T., Introduction to fluid mechanic, Seventh edition, John Wiley & Sons, Inc. 2009.

Google Scholar

[8] I.K .Knight, "The design and construction of a vertical wind tunnel for the study of untethered firebrands in flight''. Fire Technology, 37, 2001, pp.87-100.

Google Scholar

[9] S.L. Manzello,. & Suzuki, S., "The new and improved NIST Dragon's LAIR (Lofting and Ignition Research) facility'', Fire and Materials Journal, 2011.

DOI: 10.1002/fam.1123

Google Scholar